Literature DB >> 9865890

A transducer for the measurement of finger joint moments.

K L Kilgore1, R T Lauer, P H Peckham.   

Abstract

A device capable of simultaneously measuring the isometric moments generated about the metacarpophalangeal (MP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints of all four fingers has been developed. The design utilizes a four-bar linkage to transmit moments, but not forces, to the device. This linkage allows the same device to fit a wide range of hand sizes without recalibration. The device was constructed out of aluminum bars which are strapped to each joint segment and to the back of the hand. Strain gauges mounted to the aluminum bars measure the bending moment on the device, which is directly related to the moment applied about the joint center of rotation. Because of the unique design of the device, it is not necessary to have accurate measurements of the joint center of rotation in order to get accurate moment information. A single device is capable of generating independent measurement of MP extension/flexion, PIP extension/flexion, and DIP extension/flexion. Four of these devices can be used to make simultaneous measurements of all the moments generated by all four fingers. The device also acts as a splint, allowing each joint to be positioned and locked at any angle through the range of motion of the joint. The device is accurate to within +/- 5.6% of each reading for moments from 10 N x cm to 100 N x cm and within +/- 2.0 N x cm for moments of 10 N x cm or less. If the device configuration is constrained, the accuracy can be improved to +/- 0.8% of full scale (100 N x cm) and +/- 0.21 N x cm for moments of 10 N x cm or less. The device can measure both flexion and extension moments up to 100 N x cm, and can allow the joints to be fixed at any angle from approximately 10 to 80 degrees.

Entities:  

Mesh:

Year:  1998        PMID: 9865890     DOI: 10.1109/86.736157

Source DB:  PubMed          Journal:  IEEE Trans Rehabil Eng        ISSN: 1063-6528


  4 in total

1.  Development and Operation of an Experimental System to Measure the Moments Generated in the Finger Joints.

Authors:  Gregory Chagnon; Khouloud Achouri; Nathanael Connesson; Julien Gerbelot; Aurelien Courvoisier
Journal:  Bioengineering (Basel)       Date:  2022-04-22

2.  Validation of a new Equinometer device for measuring ankle range of motion in patients with cerebral palsy: An observational study.

Authors:  Axel Horsch; Saskia Kleiber; Maher Ghandour; Matthias Christoph Michael Klotz; Pit Hetto; Stefanos Tsitlakidis; Merkur Alimusaj; Marco Götze
Journal:  Medicine (Baltimore)       Date:  2022-04-29       Impact factor: 1.817

3.  Thumb force deficit after lower median nerve block.

Authors:  Zong-Ming Li; Daniel A Harkness; Robert J Goitz
Journal:  J Neuroeng Rehabil       Date:  2004-10-19       Impact factor: 4.262

4.  MUNDUS project: MUltimodal neuroprosthesis for daily upper limb support.

Authors:  Alessandra Pedrocchi; Simona Ferrante; Emilia Ambrosini; Marta Gandolla; Claudia Casellato; Thomas Schauer; Christian Klauer; Javier Pascual; Carmen Vidaurre; Margit Gföhler; Werner Reichenfelser; Jakob Karner; Silvestro Micera; Andrea Crema; Franco Molteni; Mauro Rossini; Giovanna Palumbo; Eleonora Guanziroli; Andreas Jedlitschka; Marco Hack; Maria Bulgheroni; Enrico d'Amico; Peter Schenk; Sven Zwicker; Alexander Duschau-Wicke; Justinas Miseikis; Lina Graber; Giancarlo Ferrigno
Journal:  J Neuroeng Rehabil       Date:  2013-07-03       Impact factor: 4.262

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.