Feasibility of stent placement above the sphincter of Oddi ("inside-stent") for patients with malignant biliary obstruction.

Q Liu1, G Khay, P B Cotton.   

Abstract

BACKGROUND AND STUDY AIMS: Animal studies suggest that placement of endobiliary stents wholly above the papilla (the "inside-stent") prolongs the duration of stent patency. We reviewed the cholangiographic characteristics of patients with malignant obstructive jaundice in order to evaluate the feasibility of this approach and to assist in the design of a new stent. PATIENTS AND METHODS: A review was conducted of 270 patients who had undergone endoscopic retrograde cholangiopancreatography (ERCP) for malignant obstructive jaundice at our hospital, to determine the relative frequencies of the types of cancers. The ERCP films of 59 relevant consecutive patients with malignant obstructive jaundice were studied to determine the length of the stricture, the distance between the stricture and the papilla, and the angulation of the common duct.
RESULTS: The most frequent primary cancers causing malignant obstructive jaundice were pancreatic cancer (57%), biliary cancer involving the hilum (19%, including metastatic disease), nonhilar biliary cancer (14%), and papillary cancer (10%). The length between the lower end of the stricture and the sphincter was more than 2 cm for all hilar biliary cancer, representing two-thirds of nonhilar biliary cancer cases, while it was less than 1 cm for most pancreatic cancers. There was an average angulation of 30-40 degrees in the axis of the distal common bile duct.
CONCLUSIONS: For most biliary cancers, the stricture is high enough to allow the placement of a stent fully above the papilla, but this is not possible for most pancreatic cancers (or any papillary cancers). An "inside-stent" approach would be possible in about one-third of patients with malignant obstructive jaundice if a clearance length of over 2 cm between the stricture and the sphincter is required, and in about 45% of patients if a minimum clearance of 1 cm is required. A 30-40 degrees flexion in the distal part of the stent would approximate the average angulation in the axis of the common bile duct and help to prevent dislocation.

Entities:  

Mesh:

Year:  1998        PMID: 9865557     DOI: 10.1055/s-2007-1001389

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  5 in total

1.  Evaluation of role of bile flow patterns in process of in vitro stent occlusion.

Authors:  Hongjun Zhang; Tat-Kin Tsang; Joann Pollack; Christy A Jack
Journal:  Dig Dis Sci       Date:  2002-12       Impact factor: 3.199

2.  Percutaneous placement of self-expandable metallic biliary stents in malignant extrahepatic strictures: indications of transpapillary and suprapapillary methods.

Authors:  D H Lee; J S Yu; J C Hwang; K H Kim
Journal:  Korean J Radiol       Date:  2000 Apr-Jun       Impact factor: 3.500

Review 3.  Endoscopic retrograde cholangiopancreatography in the diagnosis and management of pancreatic diseases.

Authors:  R J Shah; S P Martin
Journal:  Curr Gastroenterol Rep       Date:  2000-04

4.  Endoscopic inside stent placement is suitable as a bridging treatment for preoperative biliary tract cancer.

Authors:  Noritoshi Kobayashi; Seitaro Watanabe; Kunihiro Hosono; Kensuke Kubota; Atsushi Nakajima; Takashi Kaneko; Kazuya Sugimori; Motohiko Tokuhisa; Ayumu Goto; Ryutaro Mori; Koichi Taniguchi; Ryusei Matsuyama; Itaru Endo; Shin Maeda; Yasushi Ichikawa
Journal:  BMC Gastroenterol       Date:  2015-02-05       Impact factor: 3.067

5.  Stent placement above the sphincter of Oddi permits implementation of neoadjuvant chemotherapy in patients with initially unresectable Klatskin tumor.

Authors:  Kensuke Kubota; Sho Hasegawa; Akito Iwasaki; Takamitsu Sato; Yuji Fujita; Kunihiro Hosono; Atsushi Nakajima; Ryutaro Mori; Ryusei Matsuyama; Itaru Endo
Journal:  Endosc Int Open       Date:  2016-03-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.