Literature DB >> 9861320

Reproducibility of the low dose dexamethasone suppression test: comparison between direct plasma and salivary cortisol assays.

R M Reynolds1, H E Bendall, C B Whorwood, P J Wood, B R Walker, D I Phillips.   

Abstract

BACKGROUND: The low dose dexamethasone suppression test (DST) has been used to detect subtle variations in the feedback suppression of the hypothalamic-pituitary-adrenal axis, which may contribute to the pathogenesis of several diseases including depression, the metabolic syndrome and coronary artery disease. Little is known about the reproducibility of this test, or whether the test can be combined with analysis of salivary cortisol which would offer a significant advantage over plasma in population studies. SUBJECTS AND
DESIGN: A low dose DST was carried out in 29 healthy subjects (14 men, 15 women), aged 24-54 (mean 35.1) years, on two separate occasions 1-10 weeks apart. Following the administration of 0.25 mg dexamethasone (DXM) at 2200 h, plasma and saliva were sampled at 0830 h the next day. Cortisol was measured by radioimmunoassay in plasma and time-resolved immunofluorescent assay ('DELFIA') in saliva. Bland-Altman plots were produced for post-DXM plasma and salivary cortisol measures and used to derive a coefficient of repeatability for each measure, which describes the range of cortisol measurements within which 95% of repeated measurements will fall.
RESULTS: The baseline, pre-DXM cortisol concentrations were far more variable for saliva (mean 16.5, range 4.4-34 nmol/l) than for plasma (mean 407.5; range 232-958 nmol/l). Following DXM both measurements showed an approximately 30% suppression from baseline but the variability of salivary cortisol was much greater. From the Bland-Altman plots the 95% range for the differences about their mean was calculated and used as an indication of repeatability. For plasma 95% of differences were within 0.78 log units, indicating that a repeated measurement was approximately half as small or twice as large as the first. For saliva 95% of differences were within 1.64, indicating that a repeated measurement was approximately five times as small or five times as large as the first.
CONCLUSIONS: Assessment of dexamethasone suppression by salivary cortisol measurement is far less repeatable than the use of plasma cortisol. In the context of field studies of dexamethasone suppression, salivary cortisol measurements may only be appropriate for large numbers of subjects.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9861320     DOI: 10.1046/j.1365-2265.1998.00549.x

Source DB:  PubMed          Journal:  Clin Endocrinol (Oxf)        ISSN: 0300-0664            Impact factor:   3.478


  8 in total

1.  New targets for the clinical assessment of salivan cortisol secretion.

Authors:  R Rosmond; P Björntorp
Journal:  J Endocrinol Invest       Date:  2001-09       Impact factor: 4.256

Review 2.  Pre-analytic considerations for the proper assessment of hormones of the hypothalamic-pituitary axis in epidemiological research.

Authors:  Rachel L Derr; Scott J Cameron; Sherita Hill Golden
Journal:  Eur J Epidemiol       Date:  2006       Impact factor: 8.082

Review 3.  Reliability of hypothalamic-pituitary-adrenal axis assessment methods for use in population-based studies.

Authors:  Sherita Hill Golden; Gary S Wand; Saurabh Malhotra; Ihab Kamel; Karen Horton
Journal:  Eur J Epidemiol       Date:  2011-04-30       Impact factor: 8.082

4.  Four days of citalopram increase suppression of cortisol secretion by prednisolone in healthy volunteers.

Authors:  Carmine M Pariante; Andrew S Papadopoulos; Lucia Poon; Anthony J Cleare; Stuart A Checkley; Judie English; Robert W Kerwin; Stafford Lightman
Journal:  Psychopharmacology (Berl)       Date:  2004-06-04       Impact factor: 4.530

5.  Different responses to dexamethasone and prednisolone in the same depressed patients.

Authors:  Mario F Juruena; Anthony J Cleare; Andrew S Papadopoulos; Lucia Poon; Stafford Lightman; Carmine M Pariante
Journal:  Psychopharmacology (Berl)       Date:  2006-10-03       Impact factor: 4.530

Review 6.  Variability in laboratory parameters used for management of Cushing's syndrome.

Authors:  Francesca Pecori Giraldi; Alberto G Ambrogio
Journal:  Endocrine       Date:  2015-07-10       Impact factor: 3.633

7.  Reproducibility and utility of an overnight 0.25 mg dexamethasone suppression test as a marker for glucocorticoid sensitivity in children with asthma.

Authors:  R H Willemsen; L van Leeuwen; T A S Voorend-van Bergen; Y B de Rijke; M W Pijnenburg; E L T van den Akker
Journal:  J Endocrinol Invest       Date:  2015-06-10       Impact factor: 4.256

8.  Childhood maltreatment interacts with hypothalamic-pituitary-adrenal axis negative feedback and major depression: effects on cognitive performance.

Authors:  Neus Salvat-Pujol; Javier Labad; Mikel Urretavizcaya; Aida de Arriba-Arnau; Cinto Segalàs; Eva Real; Alex Ferrer; José M Crespo; Susana Jiménez-Murcia; Carles Soriano-Mas; José M Menchón; Virginia Soria
Journal:  Eur J Psychotraumatol       Date:  2021-03-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.