Literature DB >> 9857871

Electrical storm in patients with transvenous implantable cardioverter-defibrillators: incidence, management and prognostic implications.

S C Credner1, T Klingenheben, O Mauss, C Sticherling, S H Hohnloser.   

Abstract

OBJECTIVES: The purpose of this study was to determine the precise incidence, therapeutic options and prognostic implications of electrical storm in patients with transvenous implantable cardioverter-defibrillator (ICD) systems.
BACKGROUND: Approximately 50% to 70% of patients treated with an ICD receive appropriate device-based therapy within the first 2 years. Most arrhythmic events require only one appropriate ICD firing for termination. However, some patients receive multiple appropriate shocks during a short period of time, a condition referred to as "arrhythmic or electrical storm."
METHODS: This prospectively designed observational study comprised 136 recipients of transvenous ICDs who were followed for 403+/-242 days. Electrical storm was defined as ventricular tachycardia or fibrillation resulting in device intervention > or = 3 times during a single 24-h period.
RESULTS: During follow-up, 57/136 patients (42%) received appropriate ICD therapy. Electrical storm occurred in 14/136 patients (10%) at an average of 133+/-135 days after ICD implantation. The mean number of arrhythmic episodes constituting electrical storm was 17+/-17 (range: 3 to 50; median 8) per patient. In 12 patients, electrical storm required hospital admission. The arrhythmia cluster could be terminated by a combined therapy with beta-blockers and intravenous amiodarone whereas class I antiarrhythmic drugs were only occasionally successful. The cumulative probability of survival as estimated by the Kaplan-Meier method showed that patients with an episode of electrical storm did not have a worse outcome compared to those without such an event.
CONCLUSIONS: Electrical storm represents a frequent event in patients treated with modern ICDs. It occurs most commonly late after ICD implantation and can be managed by combined therapy with beta-blockers and amiodarone. Electrical storm does not independently confer increased mortality.

Entities:  

Mesh:

Year:  1998        PMID: 9857871     DOI: 10.1016/s0735-1097(98)00495-1

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  61 in total

Review 1.  Quality of life and psychological functioning of icd patients.

Authors:  Samuel F Sears; Jamie B Conti
Journal:  Heart       Date:  2002-05       Impact factor: 5.994

2.  [Home monitoring of an incessant VT in an ICD patient].

Authors:  N Reinsch; D Woydowski; H Schön; M Buddensiek; W Weissenberger; R Erbel; T Konorza
Journal:  Herz       Date:  2010-12-23       Impact factor: 1.443

3.  [Pharmacological therapy for ventricular arrhythmias: evidence for current treatment strategies and perspectives for the future].

Authors:  F T Wegener; G C Grönefeld; G Duray; J R Ehrlich; S H Hohnloser
Journal:  Internist (Berl)       Date:  2006-03       Impact factor: 0.743

Review 4.  The evaluation and management of electrical storm.

Authors:  Michael Eifling; Mehdi Razavi; Ali Massumi
Journal:  Tex Heart Inst J       Date:  2011

Review 5.  Electrical storm in patients with an implanted defibrillator: a matter of definition.

Authors:  Carsten W Israel; S Serge Barold
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-10       Impact factor: 1.468

6.  Antiarrhythmic induced electrical storm in Brugada syndrome: a case report.

Authors:  Sandeep Joshi; Farbod Raiszadeh; Walter Pierce; Jonathan S Steinberg
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-07       Impact factor: 1.468

Review 7.  Approach to antiarrhythmic therapy in patients with ICDs and frequent activations.

Authors:  Arnold Pinter; Paul Dorian
Journal:  Curr Cardiol Rep       Date:  2005-09       Impact factor: 2.931

Review 8.  Adjunctive therapy for recurrent ventricular tachycardia in patients with implantable cardioverter defibrillators.

Authors:  James A Reiffel
Journal:  Curr Cardiol Rep       Date:  2007-09       Impact factor: 2.931

9.  Ventricular tachycardia inducibility after radiofrequency ablation affects the outcomes in patients with coronary artery disease and implantable cardioverter-defibrillators: The role of left ventricular function.

Authors:  Andrea Colella; Marzia Giaccardi; Raffaele Molino Lova; Carmine Liccardi; Gian Franco Gensini
Journal:  J Interv Card Electrophysiol       Date:  2009-01-16       Impact factor: 1.900

Review 10.  Ventricular Tachycardia with ICD Shocks: When to Medicate and When to Ablate.

Authors:  Amir AbdelWahab; John Sapp
Journal:  Curr Cardiol Rep       Date:  2017-09-13       Impact factor: 2.931