Use of 99Tcm-MIBI in the assessment of patients with suspected recurrent breast cancer.

J B Cwikla1, J R Buscombe, S P Parbhoo, S M Kelleher, D S Thakrar, J Hinton, J Crow, A Deery, A J Hilson.   

Abstract

A prospective trial was performed to assess the accuracy of 99Tcm-methoxyisobutyl isonitrile (99Tcm-MIBI) scintimammography and X-ray mammography in 18 patients (mean age 58 years, range 46-79 years) with suspected recurrent breast cancer in the breast and/or loco-regional tissues. All patients had been diagnosed to have breast cancer 1-23 years before scintimammography. Two patients had undergone mastectomy, so that a total of 34 breasts were studied with X-ray mammography and with prone-lateral and anterior scintimammography. Any abnormalities on X-ray mammograms and scintimammograms were noted, as was any additional local or nodal uptake of 99Tcm-MIBI. The nature of any lesion seen with either modality, or in which there was a clinical suspicion of recurrence, was confirmed by cytological or histological examination of tissue samples. There were nine breasts with recurrent cancer in eight patients. X-ray mammography identified six of these cancers. 99Tcm-MIBI scintimammography identified eight of nine recurrent breast cancers (the one cancer not seen was positive on X-ray mammography). In the 26 breasts without cancer, two were reported as having changes consistent with cancer and one was reported equivocal. There were three false-positive and one equivocal scintimammograms. The accuracy of 99Tcm-MIBI scintimammography within the breast (85%) was similar to X-ray mammography (82%). Axillary lymph node recurrence occurred in five patients, four of whom were positive with 99Tcm-MIBI. An additional patient had focal uptake of 99Tcm-MIBI at the site of recurrent cancer on the anterior chest wall. In conclusion, 99Tcm-MIBI scintimammography may provide useful complementary information in patients with suspected recurrence of cancer in the breast or loco-regional tissues.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9853345     DOI: 10.1097/00006231-199807000-00006

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

1.  Scintimammography in conjunction with ultrasonography for local breast cancer recurrence in post-mastectomy breast.

Authors:  S Usmani; H Khan; N Ahmed; F Marafi; N Garvie
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

Review 2.  Use of tomographic nuclear medicine procedures, SPECT and pinhole SPECT, with cationic lipophilic radiotracers for the evaluation of axillary lymph node status in breast cancer patients.

Authors:  Giuseppe Madeddu; Angela Spanu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

3.  FDG-PET and other imaging modalities for the evaluation of breast cancer recurrence and metastases: a meta-analysis.

Authors:  LingLing Pan; Yuan Han; XiaoGuang Sun; JianJun Liu; Huang Gang
Journal:  J Cancer Res Clin Oncol       Date:  2010-01-21       Impact factor: 4.553

4.  Scintimammography as an adjunctive breast imaging technology: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2007-04-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.