Literature DB >> 9853239

The impact of stereotactic large-core needle biopsy in the treatment of patients with nonpalpable breast lesions: a study of diagnostic accuracy in 510 consecutive cases.

F J Andreu1, M Sentís, E Castañer, X Gallardo, I Jurado, M J Díaz-Ruíz, I Méndez, M Rey, R Florensa.   

Abstract

The objective of this study was to assess the usefulness of stereotactic large-core needle biopsy (LCNB) in the management of nonpalpable breast lesions (NBL) and compare it with stereotactic fine-needle aspiration biopsy (SFNA) performed simultaneously in a significant number of cases. From November 1993 through June 1997, 510 consecutive patients with NBL underwent 14-gauge LCNB with 354 women undergoing simultaneous 21-gauge SFNA in the same lesson. Mammographic findings lesion size, number of core biopsy specimens, complications and diagnoses of both techniques were analysed. Surgical biopsy, tumorectomy or mastectomy was indicated for malignancy or poor correlation between SFNA or LCNB results and clinical or radiological findings. Values of diagnostic accuracy of both LCNB and SFNA were determined. The ratio benign surgical biopsies/malignant surgical biopsies (BB/CB) of the series was calculated. A total of 171 patients underwent surgical treatment: in 31 (18.1%) a benign process or atypical ductal hyperplasia was the final diagnosis. The ratio BB/CB was 0.22. Sensitivity and specificity were 93.2 and 100%, respectively, for LCNB, and 77.2 and 92.3%, respectively, for SFNA with cytological analysis. Large-core needle biopsy provides more accurate diagnosis than SFNA in the management of nonpalpable breast lesions and obviates a surgical diagnostic procedure in a significant number of cases.

Entities:  

Mesh:

Year:  1998        PMID: 9853239     DOI: 10.1007/s003300050577

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  2 in total

1.  Investigation of tissue cellularity at the tip of the core biopsy needle with optical coherence tomography.

Authors:  Nicusor Iftimia; Jesung Park; Gopi Maguluri; Savitri Krishnamurthy; Amanda McWatters; Sharjeel H Sabir
Journal:  Biomed Opt Express       Date:  2018-01-18       Impact factor: 3.732

2.  Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

Authors:  Yao-Lung Kuo; Tsai-Wang Chang
Journal:  BMC Cancer       Date:  2010-07-16       Impact factor: 4.430

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.