Outcomes of stent-graft treatment of false lumen in aortic dissection.

M Kato1, T Matsuda, M Kaneko, T Kuratani, T Mizushima, Y Seo, H Uchida, K Kichikawa, M Maeda, K Ohnishi.   

Abstract

BACKGROUND: Stent-graft treatment for aortic disease promises to lead to a less invasive therapy than conventional surgical therapy. However, this treatment has not been established as a therapy for aortic dissection. The aim of this study was to examine the effect of stent-graft treatment of aortic dissection, as measured by follow-up data on entry site closure, clotting in the false lumen, and the outcome of the false lumen from the acute to chronic phase after operation. METHODS AND
RESULTS: We used a stent-graft of our own design to close the entry site of aortic dissection in 21 cases: 9 were acute (< 14 days), 8 subacute (< 6 months), and 4 chronic (> 6 months). Nine were type A and 12 were type B. In 15 cases, the stent-graft was inserted through the transverse arch, which had been surgically opened under median sternotomy. In the other 6 cases, the stent-graft was inserted by means of a transcatheter through a femoral artery. Using computed tomographic scans, we followed and examined clot formation in the false lumen and reduction in size of the false lumen at 3 levels: at the level of maximum aortic diameter, at the distal end of the stent-graft, and 50 mm distal to the stent-graft. The entry sites were successfully closed in 19 cases (90.4%); in the remaining 2 (both treated with a transcatheter) there was perigraft leakage into the false lumen. The hospital mortality rate of these stent-graft treatments was 14.3% (3 of 21). At 2 weeks after operation, the false lumen had completely clotted, respectively, in 100%, 77%, and 38% of cases at the 3 measurement levels. Substantial shrinkage (> 50% in diameter) of the false lumen at 6 months after the operation was observed in 72%, 60%, and 38% of cases at the respective levels. Shrinkage of the false lumen was particularly enhanced in patients treated within 6 months from the onset of dissection: The false lumen shrank by > 50% in 93%, 75%, and 50% of patients.
CONCLUSIONS: In cases of aortic dissection, the stent-graft is an effective tool for closing the entry site and promoting clot formation in the false lumen and for reducing the size of the false lumen within 6 months of the onset of dissection if the entry site has been closed.

Entities:  

Mesh:

Year:  1998        PMID: 9852919

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  19 in total

1.  Acute Aortic Dissection.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  1999-06

Review 2.  TEVAR for type B aortic dissection in Japan.

Authors:  Akihiko Usui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-12-10

3.  Endovascular treatment of thoracic dissection.

Authors:  H Rousseau; O Cosin; B Marcheix; V Chabbert; M Midulla; C Dambrin; C Cron; B Leobon; C Conil; P Massabuau; P Otal; F Joffre
Journal:  Semin Intervent Radiol       Date:  2007-06       Impact factor: 1.513

Review 4.  Treatment of uncomplicated type B aortic dissection.

Authors:  Hitoshi Matsuda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-12-05

5.  Best surgical option for arch extension of type B dissection: the endovascular approach.

Authors:  Toru Kuratani
Journal:  Ann Cardiothorac Surg       Date:  2014-05

6.  Mid-term results of endovascular treatment with the Gore TAG device for degenerative descending thoracic aortic aneurysms.

Authors:  Junji Yunoki; Toru Kuratani; Yukitoshi Shirakawa; Kei Torikai; Kazuo Shimamura; Keiwa Kin; Yoshiki Sawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-06-17

7.  Percutaneous stenting of a dissected superior mesenteric artery in a patient with previous surgical repair of Stanford type A aortic dissection.

Authors:  A Hatzidakis; M Krokidis; Z Androulakakis; M Rossi
Journal:  Hippokratia       Date:  2015 Jul-Sep       Impact factor: 0.471

8.  Current surgical results of acute type A aortic dissection in Japan.

Authors:  Yutaka Okita
Journal:  Ann Cardiothorac Surg       Date:  2016-07

9.  Surgical strategy for advanced gastric cancer with a concomitant thoracoabdominal aortic aneurysm requiring arterial reconstruction of the visceral branches.

Authors:  Yoshikazu Morimoto; Toru Kuratani; Yasuhiro Tanaka; Mitsunori Kaneko
Journal:  Surg Today       Date:  2007-08-27       Impact factor: 2.549

10.  Percutaneous interventions for treating ischemic complications of aortic dissection.

Authors:  Ajay Chavan; Herbert Rosenthal; Lars Luthe; Stefanie Pfingsten; Ingo Kutschka; Jerry Easo; Siegfried Piepenbrock; Otto Dapunt; Axel Haverich; Michael Galanski