Literature DB >> 9852787

Electrodeposited iridium oxide pH electrode for measurement of extracellular myocardial acidosis during acute ischemia.

S A Marzouk1, S Ufer, R P Buck, T A Johnson, L A Dunlap, W E Cascio.   

Abstract

In the present paper, fabrication, characterization, and physiological applications of a solid-state pH electrode are described. The pH sensing layer was based on an anodic electrodeposited iridium oxide film (AEIROF). Sputtered platinum electrodes (1 mm diameter) fabricated on flexible Kapton films or platinum wires were used as planar or cylindrical supports. Each electrode site was coated with Nafion to attenuate the interference of anionic redox species and to protect the electrode surface during in vivo measurements. Performance of the AEIROF was evaluated, for the first time, as a pH electrode and proved to have a slightly super-Nernstian response with slope of -63.5 +/- 2.2 mV/pH unit for both wire and planar sputtered platinum electrodes. Linear pH responses were obtained in the pH range 2-10. The electrodes have a working lifetime of at least 1 month with accuracy of about 0.02 pH unit and fast response time. The electrodes showed very low sensitivities for different species, such as Na+, K+, Li+, NH4+, Ca2+, Mg2+, dissolved oxygen, lactate, ascorbate, and urate, which are important for physiological applications. The electrodes were applied in extracellular pH measurements during brief regional ischemia in a swine heart and no-flow ischemia in an isolated rabbit papillary muscle. A first report on extracellular pH, K+, and lactate simultaneous measurements during no-flow ischemia using the AEIROF pH electrode and the previously described K+ and lactate electrodes is presented as well.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9852787     DOI: 10.1021/ac980608e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  20 in total

Review 1.  Monitoring rapid chemical communication in the brain.

Authors:  Donita L Robinson; Andre Hermans; Andrew T Seipel; R Mark Wightman
Journal:  Chem Rev       Date:  2008-06-25       Impact factor: 60.622

2.  A microfluidic optical platform for real-time monitoring of pH and oxygen in microfluidic bioreactors and organ-on-chip devices.

Authors:  Seyed Ali Mousavi Shaegh; Fabio De Ferrari; Yu Shrike Zhang; Mahboubeh Nabavinia; Niema Binth Mohammad; John Ryan; Adel Pourmand; Eleanor Laukaitis; Ramin Banan Sadeghian; Akhtar Nadhman; Su Ryon Shin; Amir Sanati Nezhad; Ali Khademhosseini; Mehmet Remzi Dokmeci
Journal:  Biomicrofluidics       Date:  2016-08-26       Impact factor: 2.800

3.  Electrochemical detection of catecholamine release using planar iridium oxide electrodes in nanoliter microfluidic cell culture volumes.

Authors:  Igor A Ges; Kevin P M Currie; Franz Baudenbacher
Journal:  Biosens Bioelectron       Date:  2011-12-22       Impact factor: 10.618

4.  Rapid acid extrusion response triggered by alpha(1) adrenoceptor in CHO cells.

Authors:  T Taniguchi; R Inagaki; F Suzuki; I Muramatsu
Journal:  J Physiol       Date:  2001-08-15       Impact factor: 5.182

5.  Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors.

Authors:  Jiang Yang; Tae-Joon Kwak; Xiaodong Zhang; Robert McClain; Woo-Jin Chang; Sundaram Gunasekaran
Journal:  J Vis Exp       Date:  2016-11-22       Impact factor: 1.355

6.  Stretchable, multiplexed pH sensors with demonstrations on rabbit and human hearts undergoing ischemia.

Authors:  Hyun-Joong Chung; Matthew S Sulkin; Jong-Seon Kim; Camille Goudeseune; Hsin-Yun Chao; Joseph W Song; Sang Yoon Yang; Yung-Yu Hsu; Roozbeh Ghaffari; Igor R Efimov; John A Rogers
Journal:  Adv Healthc Mater       Date:  2013-07-19       Impact factor: 9.933

7.  On-chip acidification rate measurements from single cardiac cells confined in sub-nanoliter volumes.

Authors:  Igor A Ges; Igor A Dzhura; Franz J Baudenbacher
Journal:  Biomed Microdevices       Date:  2008-06       Impact factor: 2.838

8.  Functional electron paramagnetic resonance imaging of ischemic rat heart: Monitoring of tissue oxygenation and pH.

Authors:  Artem A Gorodetsky; Igor A Kirilyuk; Valery V Khramtsov; Denis A Komarov
Journal:  Magn Reson Med       Date:  2015-08-24       Impact factor: 4.668

Review 9.  Patient-specific flexible and stretchable devices for cardiac diagnostics and therapy.

Authors:  Sarah R Gutbrod; Matthew S Sulkin; John A Rogers; Igor R Efimov
Journal:  Prog Biophys Mol Biol       Date:  2014-08-05       Impact factor: 3.667

10.  Multichamber Multipotentiostat System for Cellular Microphysiometry.

Authors:  Eduardo A Lima; Rachel M Snider; Ronald S Reiserer; Jennifer R McKenzie; Danielle W Kimmel; Sven E Eklund; John P Wikswo; David E Cliffel
Journal:  Sens Actuators B Chem       Date:  2014-12-01       Impact factor: 7.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.