Literature DB >> 9852778

Development and cellular applications of fiber optic nitric oxide sensors based on a gold-adsorbed fluorophore.

S L Barker1, R Kopelman.   

Abstract

A new design for optochemical sensors has been applied to the development of a nitric oxide selective fiber optic sensor. This sensor is composed of a fluorescein derivative dye attached to colloidal gold. The fluorescein dye rearranges as nitric oxide adsorbs onto the gold, inducing a decrease in the fluorescence intensity of the dye. This mechanism has allowed preparation of fiber optic dye-based nitric oxide sensors, which have been made ratio-metric by addition of reference dye microspheres. Previously developed fast, selective optical sensors for detection of aqueous nitric oxide involved a protein, such as cytochrome c'. The new fluorescein derivative chemical sensors have characteristics similar to those of the protein-based biosensors, including fast response times, excellent selectivity, and complete reversibility. In addition, the chemical sensors have advantages such as greater stability and commercially available components. These sensors were utilized to measure nitric oxide production by BALB/c mouse macrophages.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9852778     DOI: 10.1021/ac981016z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Analytical chemistry of nitric oxide.

Authors:  Evan M Hetrick; Mark H Schoenfisch
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2009       Impact factor: 10.745

2.  A Novel Ruthenium-based Molecular Sensor to Detect Endothelial Nitric Oxide.

Authors:  Achini K Vidanapathirana; Benjamin J Pullen; Run Zhang; MyNgan Duong; Jarrad M Goyne; Xiaozhou Zhang; Claudine S Bonder; Andrew D Abell; Christina A Bursill; Stephen J Nicholls; Peter J Psaltis
Journal:  Sci Rep       Date:  2019-02-08       Impact factor: 4.379

3.  Imaging of compartmentalised intracellular nitric oxide, induced during bacterial phagocytosis, using a metalloprotein-gold nanoparticle conjugate.

Authors:  Richard Leggett; Paul Thomas; María J Marín; Jelena Gavrilovic; David A Russell
Journal:  Analyst       Date:  2017-10-23       Impact factor: 4.616

4.  pH and Urea Estimation in Urine Samples using Single Fluorophore and Ratiometric Fluorescent Biosensors.

Authors:  Rashmi Chaudhari; Abhijeet Joshi; Rohit Srivastava
Journal:  Sci Rep       Date:  2017-07-19       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.