Literature DB >> 985177

["Zuggurtungs"-hip joint endoprosthesis (author's transl)].

G Ritter, A Grünert, C H Schweikert.   

Abstract

On the basis of theoretical and experimental investigations to the problem of endoprosthetic replacement of the hip joint and the forces concerning the anchorage of the prosthesis a new model of prosthesis was developed and realized for practical use. In this paper this new "Zuggurtungs-Hüftendoprothese" and the biomechanical principles are described in detail. The biomechanically derived postulations realized in the new prosthesis which are of primary importance to avoid the mechanical complications of loosening and breaking of the prosthesis are also decisive when optimal materials are used. They allow the implantation without bone cement by the primary acievable stable anchorage.

Mesh:

Year:  1976        PMID: 985177     DOI: 10.1007/bf00415298

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  15 in total

1.  Anchorage of the femoral head prosthesis to the shaft of the femur.

Authors:  J CHARNLEY
Journal:  J Bone Joint Surg Br       Date:  1960-02

2.  Arthroplasty of the hip. A new operation.

Authors:  J Charnley
Journal:  Lancet       Date:  1961-05-27       Impact factor: 79.321

3.  [Fixing endoprostheses without cement using the principle of "weightbearing ribbing" (author's transl)].

Authors:  H Mittelmeier
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-02

4.  [Rotating total endoprosthesis of the hip joint].

Authors:  B G Weber
Journal:  Z Orthop Ihre Grenzgeb       Date:  1970-01

5.  [Is Al2O3 ceramic suitable for material used as sliding components in total joint replacements? (author's transl)].

Authors:  M Ungethüm; H J Refior
Journal:  Arch Orthop Unfallchir       Date:  1974

6.  [Biomechanical caused of loosening and breaking of the hip joint prothesess (author's transl)].

Authors:  G Ritter; A Grünert; C H Schweikert
Journal:  Arch Orthop Unfallchir       Date:  1973-11-13

7.  [Experimental investigations to the problem of anchorage of the hip joint endoprostheses (author's transl)].

Authors:  A Grünert; G Ritter
Journal:  Arch Orthop Unfallchir       Date:  1973-11-13

8.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

9.  [Total prosthesis of the hip joint].

Authors:  C H Schweikert; R Rahmanzadeh; F Gaiao; D Wessinghage
Journal:  Dtsch Med Wochenschr       Date:  1971-04-09       Impact factor: 0.628

Review 10.  [X-ray evaluation of the total prosthesis in hip-joint replacement and its complications].

Authors:  H Weigand; G Ritter
Journal:  Dtsch Med Wochenschr       Date:  1974-10-11       Impact factor: 0.628

View more
  1 in total

1.  [The force flow in hip joint-endoprostheses (author's transl)].

Authors:  H Röhrle; R Scholten; W Sollbach; G Ritter; A Grünert
Journal:  Arch Orthop Unfallchir       Date:  1977-07-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.