Literature DB >> 9847572

[Clinical results of endovascular stent graft repair for fifty cases of thoracic aortic aneurysms].

S Kawaguchi1, S Ishimaru, T Shimazaki, Y Yokoi, N Koizumi, Y Obitsu, M Ishikawa.   

Abstract

Between February 1995 and December 1997, 50 cases (55 lesions) of thoracic aortic aneurysms including 20 cases of aortic dissections were treated with an endovascular technique using the stent grafts. All patients were treated in the operating room under general anesthesia and the stent grafts were implanted through 18 Fr. or 20 Fr. sheaths via femoral arteries under fluoroscopic guidance. The stent graft was composed of several units of self-expanding stainless-steel Z stents covered with an ultra-thin polyester fabric. Stent graft deployment was technically successful in 53 of 55 lesions (delivery success rate: 96.4%). Exclusion of the aneurysms and entry closing without endoleak were achieved within two weeks after the operation in 43 of 53 lesions (initial success rate: 81.1%). Endoleak was found in 10 lesions (minor endoleak: 8 and major endoleak: 2 lesions). Two patients died in the periopertive period of delivery failures as injury to external iliac artery and damage to the delivery sheath caused by tortuous and narrow access routes. Endovascular stent graft repair of thoracic aortic aneurysms is minimally invasive operation in comparison with conventional surgical graft replacement with extracorporeal circulation. These early results suggest that the stent graft repair is possibly safe and useful treatment for the patients of thoracic aortic aneurysms especially in high risk patients. However, careful long-term follow-up is necessary to prove the value and the effects of this endovascular treatment and improvement of the stent graft system and technical training of endovascular surgery for operators are required to reduce the delivery failure and to determine the stent graft repair is reliable treatment.

Entities:  

Mesh:

Year:  1998        PMID: 9847572     DOI: 10.1007/bf03217857

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  6 in total

1.  Transluminally-placed coilspring endarterial tube grafts. Long-term patency in canine popliteal artery.

Authors:  C T Dotter
Journal:  Invest Radiol       Date:  1969 Sep-Oct       Impact factor: 6.016

2.  Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms.

Authors:  U Blum; G Voshage; J Lammer; F Beyersdorf; D Töllner; G Kretschmer; G Spillner; P Polterauer; G Nagel; T Hölzenbein
Journal:  N Engl J Med       Date:  1997-01-02       Impact factor: 91.245

3.  Percutaneous femoropopliteal graft placement.

Authors:  A H Cragg; M D Dake
Journal:  Radiology       Date:  1993-06       Impact factor: 11.105

4.  Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms.

Authors:  M D Dake; D C Miller; C P Semba; R S Mitchell; P J Walker; R P Liddell
Journal:  N Engl J Med       Date:  1994-12-29       Impact factor: 91.245

5.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.

Authors:  J C Parodi; J C Palmaz; H D Barone
Journal:  Ann Vasc Surg       Date:  1991-11       Impact factor: 1.466

6.  Endovascular stent-graft repair of thoracic aortic aneurysms.

Authors:  R S Mitchell; M D Dake; C P Sembra; T J Fogarty; C K Zarins; R P Liddel; D C Miller
Journal:  J Thorac Cardiovasc Surg       Date:  1996-05       Impact factor: 5.209

  6 in total
  3 in total

1.  Total aortic arch aneurysm repair using a stent graft without cardiac or cerebral ischemia.

Authors:  Junichi Naganuma; Mikio Ninomiya; Takeshi Miyairi; Yutaka Kotsuka; Shinichi Takamoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-07

2.  Case report of an endovascular repair of a residual type A dissection using a not CE not FDA-approved Najuta thoracic stent graft system.

Authors:  N Mangialardi; S Ronchey; A Malaj; M Lachat; E Serrao; V Alberti; S Fazzini
Journal:  Medicine (Baltimore)       Date:  2015-01       Impact factor: 1.889

3.  Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones.

Authors:  Toshio Takayama; Patrick J Phelan; Jon S Matsumura
Journal:  J Vasc Surg Cases Innov Tech       Date:  2017-04-25
  3 in total