Literature DB >> 9845652

Comparison of simultaneous electroencephalographic and mental status monitoring during carotid endarterectomy with regional anesthesia.

J Stoughton1, R L Nath, W M Abbott.   

Abstract

PURPOSE: This study examines the accuracy of intraoperative electroencephalographic (EEG) monitoring for the detection of cerebral ischemia by comparing EEG with simultaneous mental status evaluation (MSE) during carotid endarterectomy in awake patients.
METHODS: Between 1994 and 1997, 208 consecutive carotid endarterectomies were prospectively evaluated for cerebral function during surgery with simultaneous MSE and EEG monitoring. Regional anesthesia (RA), which consisted of superficial cervical block, was chosen preferentially in 75% of the cases, with general anesthesia (GA) reserved for the patients who did not fulfill the criteria for RA. When available, 8-channel EEG monitoring was performed (59% with RA and 55% with GA).
RESULTS: The EEG was a reliable predictor in comparison with MSE in most but not all cases of cerebral ischemia. Significant neurologic changes were noted using MSE in 4 of 89 patients (4.5%) that were not detected using EEG (false negative results). Conversely, 6 of 89 cases (6.7%) showed unilateral slowing without associated changes in MSE (false positive results). For the awake patients, 21 of 150 cases (14%) showed MSE changes that required a shunt. By contrast, 9 of 32 GA cases (28%) showed EEG changes that would have led to shunting (P = NS). In the RA group, there were no strokes versus 3 of 58 cases (5.2%) with strokes in the GA group. Two of 150 cases (0.1%) had transient ischemic attacks in the RA group. There was 1 myocardial infarction in the GA group; no deaths occurred in this series.
CONCLUSION: EEG monitoring yielded a significant number of false positive (6.7%) and false negative (4.5%) results in the detection of neurologic deficits when compared with MSE in the awake patients. In this series, the preferential use of RA resulted in less shunt use and was possibly associated with a lower stroke rate.

Entities:  

Mesh:

Year:  1998        PMID: 9845652     DOI: 10.1016/s0741-5214(98)70027-8

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

1.  Preoperative magnetic resonance angiography as a predictive test for cerebral ischemia during carotid endarterectomy.

Authors:  Sung Shin; Tae-Won Kwon; Yong-Pil Cho; Ji Hoon Shin; Ann Yi; Hyangkyung Kim; Geun Eun Kim
Journal:  World J Surg       Date:  2013-03       Impact factor: 3.352

2.  Carotid endarterectomy in awake patients: safety, tolerability and results.

Authors:  Célio Teixeira Mendonça; Jerônimo A Fortunato; Cláudio A de Carvalho; Janaina Weingartner; Otávio R M Filho; Felipe F Rezende; Luciane P Bertinato
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Oct-Dec

3.  Cerebral monitoring during carotid endarterectomy by transcranial Doppler ultrasonography.

Authors:  Woo-Sung Yun
Journal:  Ann Surg Treat Res       Date:  2017-01-31       Impact factor: 1.859

4.  Cost-Effectiveness of Two Decision Strategies for Shunt Use During Carotid Endarterectomy.

Authors:  Joe L P Kolkert; Rolf H H Groenwold; Vanessa J Leijdekkers; Joep Ter Haar; Clark J Zeebregts; Anco Vahl
Journal:  World J Surg       Date:  2017-11       Impact factor: 3.352

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.