Literature DB >> 9845212

Automated measurement of myofiber disarray in transgenic mice with ventricular expression of ras.

W J Karlon1, J W Covell, A D McCulloch, J J Hunter, J H Omens.   

Abstract

Quantitative assessment of myofiber disarray associated with diseases such as familial hypertrophic cardiomyopathy (FHC) can be performed by estimating local angular deviation of fiber orientation in histologic sections. The large number of measurements required to estimate angular deviation prohibits manual measurement. We describe methods for automated measurement of local orientation and angular deviation in tissue sections from transgenic mice with ventricular expression of ras, proposed as a model of FHC. Images of histologic tissue sections from normal and transgenic mice were analyzed using image processing techniques to estimate local orientation of myofibers. Results from the automated methods were compared with manual measurements. Automated methods estimated differing mean orientation in 7-20% of normal sections and 17-29% of transgenic tissue sections with differing dispersions in 23-30% of normal sections and 25% of transgenic tissue sections. Automated methods estimate 24.47+/-13.03% of total ventricular mass affected by disarray that is comparable to a previous estimate of 21.7% in the same mouse model. Automated methods are a rapid and accurate alternative to manual measurement for estimation of mean orientation and angular deviation in myocardial tissue sections. Differences between manual and automated methods may be attributed to the substantially larger number of measurements made by automated methods. Automated methods are particularly appropriate for use in determining local variation in orientation such as focal myofiber disarray associated with FHC. The generality of these methods suggests they may have use in other biological fields such as quantifying cellular alignment.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9845212     DOI: 10.1002/(SICI)1097-0185(199812)252:4<612::AID-AR12>3.0.CO;2-1

Source DB:  PubMed          Journal:  Anat Rec        ISSN: 0003-276X


  61 in total

1.  Local tissue geometry determines contractile force generation of engineered muscle networks.

Authors:  Weining Bian; Mark Juhas; Terry W Pfeiler; Nenad Bursac
Journal:  Tissue Eng Part A       Date:  2012-01-04       Impact factor: 3.845

2.  A theoretical and non-destructive experimental approach for direct inclusion of measured collagen orientation and recruitment into mechanical models of the artery wall.

Authors:  Michael R Hill; Xinjie Duan; Gregory A Gibson; Simon Watkins; Anne M Robertson
Journal:  J Biomech       Date:  2012-02-02       Impact factor: 2.712

3.  Development of a polarized hyperspectral microscope for cardiac fiber orientation imaging.

Authors:  Ximing Zhou; James Dormer; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-02-25

4.  Image-based estimation of ventricular fiber orientations for personalized modeling of cardiac electrophysiology.

Authors:  Fijoy Vadakkumpadan; Hermenegild Arevalo; Can Ceritoglu; Michael Miller; Natalia Trayanova
Journal:  IEEE Trans Med Imaging       Date:  2012-01-18       Impact factor: 10.048

5.  Three-dimensional models of individual cardiac histoanatomy: tools and challenges.

Authors:  Rebecca A B Burton; Gernot Plank; Jürgen E Schneider; Vicente Grau; Helmut Ahammer; Stephen L Keeling; Jack Lee; Nicolas P Smith; David Gavaghan; Natalia Trayanova; Peter Kohl
Journal:  Ann N Y Acad Sci       Date:  2006-10       Impact factor: 5.691

6.  A 2D-computer model of atrial tissue based on histographs describes the electro-anatomical impact of microstructure on endocardiac potentials and electric near-fields.

Authors:  Fernando O Campos; Thomas Wiener; Anton J Prassl; Helmut Ahammer; Gernot Plank; Rodrigo Weber Dos Santos; Damián Sánchez-Quintana; Ernst Hofer
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

7.  Bimodal biophotonic imaging of the structure-function relationship in cardiac tissue.

Authors:  William J Hucker; Crystal M Ripplinger; Christine P Fleming; Vadim V Fedorov; Andrew M Rollins; Igor R Efimov
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

8.  A novel cylindrical biaxial computer-controlled bioreactor and biomechanical testing device for vascular tissue engineering.

Authors:  Michael T Zaucha; Julia Raykin; William Wan; Robert Gauvin; Francois A Auger; Lucie Germain; Thomas E Michaels; Rudolph L Gleason
Journal:  Tissue Eng Part A       Date:  2009-11       Impact factor: 3.845

9.  Engineered skeletal muscle tissue networks with controllable architecture.

Authors:  Weining Bian; Nenad Bursac
Journal:  Biomaterials       Date:  2008-12-12       Impact factor: 12.479

10.  A custom image-based analysis tool for quantifying elastin and collagen micro-architecture in the wall of the human aorta from multi-photon microscopy.

Authors:  Ryan G Koch; Alkiviadis Tsamis; Antonio D'Amore; William R Wagner; Simon C Watkins; Thomas G Gleason; David A Vorp
Journal:  J Biomech       Date:  2014-01-20       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.