Literature DB >> 9842822

In vitro investigation of cerebrospinal fluid leakage after dural puncture with various spinal needles.

D Holst1, M Möllmann, C Ebel, R Hausman, M Wendt.   

Abstract

UNLABELLED: Postspinal headache is one of the most common complications of spinal anesthesia and has repeatedly led to controversy concerning needle size and configuration. In an in vitro investigation, we measured cerebrospinal fluid (CSF) leakage with Sprotte, Whitacre, Quincke, and Atraucan needles under physiological conditions in human dura. The puncture characteristics were examined under an electron microscope. The pencil-point needles show 2-3 times less leakage of CSF compared with the cutting Quincke needles of corresponding size. Between the Sprotte and the Whitacre needles, there were no significant differences. The least loss of CSF occurred with the 26-gauge Atraucan needle. Under the electron microscope, a sharply delineated, persistent perforation channel was shown with the Quincke needles, which may explain the high CSF loss. With pencil-point needles, which push the tissue apart bluntly, a large opening on the inside is found, with some tearing of the dura. However, in contrast to the cutting needles, a persistent perforation channel is not manifested. The 26-gauge Atraucan needle, which both cuts and pushes apart conically, shows a relatively discrete opening on the inside, with slight tears in the dura and arachnoidea but without a visible perforation channel. The results of our study show that larger needles (26-gauge Atraucan) that are easier to handle can lead to good and, in some cases even better, puncture results if they have characteristics of both the cutting and the pencil-point needles. IMPLICATIONS: We compared several brands of pencil-point and standard cutting spinal needles of varying sizes. All pencil-point needles had less cerebrospinal fluid leakage, the least loss occurring with 26-gauge Atraucan needles. Electron microscopic examination of the dura after puncture showed characteristic findings with each needle type. We conclude that the combined cutting and pencil-point characteristics seen in the Atraucan needle may have clinical advantages.

Entities:  

Mesh:

Year:  1998        PMID: 9842822     DOI: 10.1097/00000539-199812000-00022

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

1.  Headache after diagnostic lumbar puncture. Using 20 gauge needle is blunderbuss technique.

Authors:  J S Smeltzer
Journal:  BMJ       Date:  2001-04-21

Review 2.  Finer gauge of cutting but not pencil-point needles correlate with lower incidence of post-dural puncture headache: a meta-regression analysis.

Authors:  Andres Zorrilla-Vaca; Ryan Healy; Carolina Zorrilla-Vaca
Journal:  J Anesth       Date:  2016-07-28       Impact factor: 2.078

3.  High incidence of post-dural puncture headache in patients with spinal saddle block induced with Quincke needles for anorectal surgery: a randomised clinical trial.

Authors:  Marc D Schmittner; Tom Terboven; Michael Dluzak; Andrea Janke; Marc E Limmer; Christel Weiss; Dieter G Bussen; Marc A Burmeister; Grietje C Beck
Journal:  Int J Colorectal Dis       Date:  2010-02-11       Impact factor: 2.571

4.  Influence of the pre-operative time in upright sitting position and the needle type on the incidence of post-dural puncture headache (PDPH) in patients receiving a spinal saddle block for anorectal surgery.

Authors:  Marc D Schmittner; Nicole Urban; Andrea Janke; Christel Weiss; Dieter G Bussen; Marc A Burmeister; Grietje C Beck
Journal:  Int J Colorectal Dis       Date:  2010-07-22       Impact factor: 2.571

Review 5.  The status of diagnosis and treatment to intracranial hypotension, including SIH.

Authors:  Jin-Ping Lin; Shu-Dong Zhang; Fei-Fang He; Min-Jun Liu; Xiao-Xu Ma
Journal:  J Headache Pain       Date:  2017-01-13       Impact factor: 7.277

6.  The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients.

Authors:  Mehmet Salim Akdemir; Ayhan Kaydu; Yonca Yanlı; Mehtap Özdemir; Erhan Gökçek; Haktan Karaman
Journal:  Anesth Essays Res       Date:  2017 Apr-Jun