Are electronic thermometry techniques suitable alternatives to traditional mercury in glass thermometry techniques in the paediatric setting?

J Smith1.   

Abstract

Three thermometers, mercury in glass, Becton-Dickinson digital and IVAC tympanic membrane thermometer, were compared. The study was designed to test the null hypothesis that there is no difference between the thermometer recordings, meaning that electronic thermometry is a suitable alternative to traditional mercury in glass thermometry. Children aged between 0 and 15 years old were entered into the study, n = 114. Standard procedures were used throughout the study to minimize the risk of errors in the data collection and technical errors were recorded. The data were analysed using graphical techniques described by Bland and Altman. The differences between the temperature recordings were plotted against their mean (the estimated true value), with the bias and limits of agreement (2 standard deviations from the mean) calculated for the mercury in glass/digital, mercury in glass/tympanic and digital/tympanic temperature recordings. The range of temperatures were 35.1 degrees C-38.5 degrees C, with a mean of 36.85 degrees C for the mercury in glass thermometer, 36.8 degrees C for the digital thermometer and 36.65 degrees C for the tympanic thermometer. The bias for each comparison was 0.36 degrees C, 0.21 degrees C and 0.17 degrees C and the limits of agreement were wide, -0.516 degrees C to 1.234 degrees C, -0.84 degrees C to 1.252 degrees C and -0.940C to 1.244 degrees C for the mercury in glass/digital, mercury in glass/tympanic and digital/ tympanic recordings respectively. A difference of 0.2 degrees C is usually accepted for clinical practice, therefore the null hypothesis was rejected.

Entities:  

Mesh:

Year:  1998        PMID: 9840874     DOI: 10.1046/j.1365-2648.1998.00745.x

Source DB:  PubMed          Journal:  J Adv Nurs        ISSN: 0309-2402            Impact factor:   3.187


  3 in total

1.  Body temperature measurement in paediatrics: Which gadget should we believe?

Authors:  Joan L Robinson
Journal:  Paediatr Child Health       Date:  2004-09       Impact factor: 2.253

2.  Incidence and seasonality of hypothermia among newborns in southern Nepal.

Authors:  Luke C Mullany; Joanne Katz; Subarna K Khatry; Steven C Leclerq; Gary L Darmstadt; James M Tielsch
Journal:  Arch Pediatr Adolesc Med       Date:  2010-01

3.  Neonatal hypothermia in Northern Uganda: a community-based cross-sectional study.

Authors:  David Mukunya; James K Tumwine; Victoria Nankabirwa; Beatrice Odongkara; Justin B Tongun; Agnes A Arach; Josephine Tumuhamye; Agnes Napyo; Vivian Zalwango; Vicentina Achora; Milton W Musaba; Grace Ndeezi; Thorkild Tylleskär
Journal:  BMJ Open       Date:  2021-02-11       Impact factor: 2.692

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.