Literature DB >> 9839985

Virtual cisternoscopy of intracranial vessels: a novel visualization technique using virtual reality.

F Fellner1, M Blank, C Fellner, H Böhm-Jurkovic, W Bautz, W A Kalender.   

Abstract

This paper introduces a different visualization method which we call "virtual cisternoscopy" using 3D MRA data sets. Virtual cisternoscopy uses well known tools, such as perspective volume rendering (pVR), fly-through techniques, and interactive visualization and combines them to a new approach featuring motion to resolve spatial relationships of intracranial vessels and vascular malformations. With a dedicated flight protocol extraluminal topography of intracranial arteries was analyzed using pVR. For evaluation of difficult vascular malformations extraluminal views are necessary. Therefore, movies of pVR views were produced simulating virtual tracks of neurosurgical flexible endoscopes, by flying around the intracranial vessels and vascular malformations within the cisterns. Endoluminal views were acquired additionally for precise evaluation of cases with complex vessel topography. Two healthy volunteers and three patients were examined. Comparing MIP and pVR images relevant advantages of pVR were found, such as depth information, perspective, lighting, and color. In contrast to MIP and source images of the MRA data set, virtual cisternoscopy of an aneurysm of the left middle cerebral artery demonstrated clearly an early origin of an artery in the region of the aneurysm neck/sac. In this case only virtual cisternoscopy led to the correct therapeutical decision. In a newborn, the type of a vein of Galen aneurysmal malformation could only be evaluated reliably by means of virtual cisternoscopy. The third case of a patient with a clipped aneurysm was evaluated more easily with virtual cisternoscopy than with DSA. In conclusion, virtual cisternoscopy may improve the pretherapeutic visualization of intracranial vascular malformations.

Entities:  

Mesh:

Year:  1998        PMID: 9839985     DOI: 10.1016/s0730-725x(98)00113-1

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

Review 1.  New developments in the detection of vulnerable plaque.

Authors:  M Naghavi; M Madjid; M R Khan; R M Mohammadi; J T Willerson; S W Casscells
Journal:  Curr Atheroscler Rep       Date:  2001-03       Impact factor: 5.113

2.  Virtual arterial endoscopy as a diagnostic aid in a patient with basilar artery fenestration and thromboembolic pontine infarct.

Authors:  Axel Scherer; Mario Siebler; Albrecht Aulich
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

3.  Intraoperative evaluation of aneurysmal architecture: comparative study with transluminal images of 3D MR and CT angiograms.

Authors:  Toru Satoh; Keisuke Onoda; Shoji Tsuchimoto
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.