Literature DB >> 9834945

Evaluation of atomizer performance in production of respirable spray-dried particles.

C A Dunbar1, N M Concessio, A J Hickey.   

Abstract

The purpose of this study was to analyze atomizer performance in the production of respirable spray-dried particles. An ultrasonic nebulizer and a plain-jet airblast atomizer were evaluated in an open cycle, cocurrent spray-drying tower using a 0.5% w/v disodium fluorescein solution. The plain-jet airblast atomizer produced smaller initial droplet sizes (D32 = 4.5-4.8 microns) relative to the ultrasonic nebulizer (D32 = 20-48 microns) over a range of atomizer operating conditions. The airblast atomizer was selected for further analysis in two spray-drying tower configurations: grounded and electrostatically charged. The spray-dried particles produced by the airblast atomizer were of a size range (mass median aerodynamic diameter [MMAD] < 1.6 microns) suitable for inhalation. Significant differences were observed for the grounded and electrostatically charged tower configurations, the latter producing the smaller median particle size at the expense of decreased collection efficiency. The electrostatically charged tower was size selective because of diffusion charging, retaining particles with an aerodynamic diameter (Dae) in the range 1 < Dae < 2 microns. The particle size was reduced with decreasing ambient relative humidity, although a controlled study of this parameter would be required to explicitly define its effects.

Entities:  

Mesh:

Year:  1998        PMID: 9834945     DOI: 10.3109/10837459809028624

Source DB:  PubMed          Journal:  Pharm Dev Technol        ISSN: 1083-7450            Impact factor:   3.133


  4 in total

Review 1.  Particle engineering for pulmonary drug delivery.

Authors:  Albert H L Chow; Henry H Y Tong; Pratibhash Chattopadhyay; Boris Y Shekunov
Journal:  Pharm Res       Date:  2007-03       Impact factor: 4.200

Review 2.  Materials for pharmaceutical dosage forms: molecular pharmaceutics and controlled release drug delivery aspects.

Authors:  Heidi M Mansour; Minji Sohn; Abeer Al-Ghananeem; Patrick P Deluca
Journal:  Int J Mol Sci       Date:  2010-09-15       Impact factor: 5.923

3.  Effect of polymer content and molecular weight on the morphology and heat- and moisture-induced transformations of spray-dried composite particles of amorphous lactose and poly(vinylpyrrolidone).

Authors:  Jonas Berggren; Göran Alderborn
Journal:  Pharm Res       Date:  2003-07       Impact factor: 4.200

Review 4.  Inhalation drug delivery devices: technology update.

Authors:  Mariam Ibrahim; Rahul Verma; Lucila Garcia-Contreras
Journal:  Med Devices (Auckl)       Date:  2015-02-12