Literature DB >> 9834304

Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty. Restenosis Stent Study Group.

R Erbel1, M Haude, H W Höpp, D Franzen, H J Rupprecht, B Heublein, K Fischer, P de Jaegere, P Serruys, W Rutsch, P Probst.   

Abstract

BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions.
METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel.
RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04).
CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.

Entities:  

Mesh:

Year:  1998        PMID: 9834304     DOI: 10.1056/NEJM199812033392304

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  21 in total

Review 1.  Radiation medicine innovations for the new millenium.

Authors:  Dwight E Heron; Karen D Godette; Ray A Wynn; V Elayne Arterbery; Oscar A Streeter; Mack Roach; Joseph R Simpson; Melissa Blough; Charles R Thomas
Journal:  J Natl Med Assoc       Date:  2003-01       Impact factor: 1.798

2.  Assessment of coronary artery stent patency by electron-beam CT.

Authors:  Friedrich D Knollmann; Jörg Möller; Axel Gebert; Christian Bethge; Roland Felix
Journal:  Eur Radiol       Date:  2004-06-03       Impact factor: 5.315

3.  First in-human randomized comparison of an anodized niobium stent versus a standard stainless steel stent--an intravascular ultrasound and angiographic two-center study: the VELA study.

Authors:  F Beier; M Gyöngyösi; T Raeder; E von Eckardstein-Thumb; W Sperker; P Albrecht; C Spes; D Glogar; H Mudra
Journal:  Clin Res Cardiol       Date:  2006-07-03       Impact factor: 5.460

4.  Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis.

Authors:  Henry Y Chen; James Hermiller; Anjan K Sinha; Michael Sturek; Luoding Zhu; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2009-03-19

5.  Are "treatment" bare metal stents superior to "control" bare metal stents? A meta-analytic approach.

Authors:  David M Kent; Thomas A Trikalinos
Journal:  Am Heart J       Date:  2008-01-18       Impact factor: 4.749

6.  Treatment and Short-Term Follow-up of Symptomatic Atherosclerotic Intracranial Artery Stenosis by Stent-Assisted Angioplasty.

Authors:  Miao Zhongrong; Ling Feng; Li Shengmao; Zhu Fengshui; Hua Yang; Wang Moli
Journal:  Interv Neuroradiol       Date:  2004-10-22       Impact factor: 1.610

7.  Murine model of femoral artery wire injury with implantation of a perivascular drug delivery patch.

Authors:  Victoria Le; Collin G Johnson; Jonathan D Lee; Aaron B Baker
Journal:  J Vis Exp       Date:  2015-02-10       Impact factor: 1.355

Review 8.  Drug-eluting stents versus bare-metal stents for acute coronary syndrome.

Authors:  Joshua Feinberg; Emil Eik Nielsen; Janette Greenhalgh; Juliet Hounsome; Naqash J Sethi; Sanam Safi; Christian Gluud; Janus C Jakobsen
Journal:  Cochrane Database Syst Rev       Date:  2017-08-23

9.  Successful Percutaneous Balloon Angioplasty in a Patient Presenting With STEMI and Acute Intracranial Hemorrhage.

Authors:  Aref Obagi; Matthew Schoenfeld
Journal:  Cureus       Date:  2021-05-22

10.  Transileocolic venous balloon dilatation for the management of primary and recurrent portal venous stenosis after living donor liver transplantation in children.

Authors:  Ryo Hotta; Ken Hoshino; Seishi Nakatsuka; Shioko Nakao; Jun Okamura; Yohei Yamada; Koji Komori; Yasushi Fuchimoto; Hideaki Obara; Shigeyuki Kawachi; Minoru Tanabe; Yasuhide Morikawa; Subaru Hashimoto; Masaki Kitajima
Journal:  Pediatr Surg Int       Date:  2007-10       Impact factor: 1.827

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.