G Beaumier-Gallon1, J Lanfranchi, M F Vergnes, D Lairon, J Pastor, A M Pauli, H Portugal.
Abstract
An assay was developed to quantify deuterated cholesterol (used as a tracer) and cholesterol using gas chromatography-mass spectrometry. Ergosterol and epicoprostanol were used as internal standards. Deuterated cholesterol was quantified by comparing its peak area to that of epicoprostanol and cholesterol to ergosterol. The mean absolute recovery in spiked serum was 99.96%; the precision was in the range 0.16-10.9% and accuracy 90.4-100%; the limit of detection in plasma was 3x10(-5) mmol l(-1). Using two internal standards, the method described herein seems particularly suitable for application in humans i.e., measuring traces of deuterated cholesterol (range: 0-6.26 x 10(-4) mmol l(-1)) along with natural cholesterol (range: 0.065-4.42 mmol l(-1)) in human plasma and lipid fractions postprandially.Entities: