Chronic evaluation of orthotopically implanted bileaflet mechanical aortic valves in adult domestic sheep.

C T Salerno1, T S Pederson, D W Ouyang, R M Bolman, R W Bianco.   

Abstract

This study was intended to develop a technically feasible and reproducible model for chronic hemodynamic and mechanical evaluation of orthotopically implanted bileaflet mechanical aortic valves in adult domestic sheep. Three adult sheep (mean age 22 weeks, mean weight 76 kg) underwent aortic valve replacement using 19-mm bileaflet aortic valves. Standard cardiopulmonary bypass techniques were followed, including mild hemodilution, systemic hypothermia, and cardioplegic arrest. After performing a left fourth intercostal thoracotomy, the valves were placed using interrupted 3-0 Ticron (Davis + Geck) inverted mattress sutures through a transverse aortotomy. The average cardiopulmonary bypass time was 58+/-1 min. No chronic anticoagulation was used. There were no surgical complications. All three animals (100%) remained clinically well until elective sacrifice after postoperative day 150. The average cardiac output for the animals at sacrifice was 3.8+/-1.0 L/min. The mean aortic ejection velocity was 304.7+/-47.3 cm/s and the mean pressure gradient was 24.6+/-6.7 mm Hg. There was no clinically significant thrombus formation or paravalvular leaks. Thus, we have demonstrated that it is technically feasible to orthotopically implant mechanical aortic valves in sheep. There are several features that contribute to the success of this model, including use of a transverse aortotomy, adequate de-airing, and the use of mild hemodilution during bypass. We believe that this model is reproducible and can be used to study other valve designs. In addition, this model allows for site-specific preclinical assessment of new or modified mechanical heart valves.

Entities:  

Mesh:

Year:  1998        PMID: 9827651     DOI: 10.3109/08941939809032210

Source DB:  PubMed          Journal:  J Invest Surg        ISSN: 0894-1939            Impact factor:   2.533


  3 in total

1.  Strategies to Improve Survival from Surgery for Heart Valve Implantation in Sheep.

Authors:  Annemijn Vis; Jan Cam Lammers; Roel de Vroege; Martijn Mj van Nieuwburg; Marlijn S Jansen; Joyce Mj Visser; Bart Meuris; Paul F Gründeman; Jolanda Kluin
Journal:  Comp Med       Date:  2021-06-03       Impact factor: 0.982

2.  Transesophageal Echocardiography in Healthy Young Adult Male Baboons (Papio hamadryas anubis): Normal Cardiac Anatomy and Function in Subhuman Primates Compared to Humans.

Authors:  Arthur A Bert; William B Drake; Rachael W Quinn; Kathleen M Brasky; James E O'Brien; Gary K Lofland; Richard A Hopkins
Journal:  Prog Pediatr Cardiol       Date:  2013-08-01

3.  Development of an animal experimental model for a bileaflet mechanical heart valve prosthesis.

Authors:  Suk Jung Choo; Kun Il Kim; Nam Hee Park; Jong Min Song; In Cheol Choi; Jee Yeon Shim; Sang Kwon Lee; Young Joo Kwon; Chang Nyung Kim; Jae Won Lee
Journal:  J Korean Med Sci       Date:  2004-02       Impact factor: 2.153