Literature DB >> 9826217

Body composition assessment by dual-energy x-ray absorptiometry: comparison of prone and supine measurements.

I Lambrinoudaki1, E Georgiou, G Douskas, G Tsekes, M Kyriakidis, C Proukakis.   

Abstract

The aim of the study was to assess whether changes in the interposition of body compartments affect the results of body composition measurements by dual-energy x-ray absorptiometry (DEXA) in the fan-beam mode. Thirty healthy subjects underwent two sequential measurements: the first was performed in the supine position as described by the manufacturer, and the second in the prone position. Estimates of body composition were compared between the two measurements. Mean body weight did not differ between measurements ([mean+/-SD] supine vprone, 68.561+/-12.461 v 68.589+/-12.469 kg). Mean bone mineral content (BMC) was lower in the prone position versus the supine position. When the head was excluded, this difference reached statistical significance (supine v prone, 1,738+/-361 v 1,688+/-360 g, P=.0001). The mean fat tissue mass (FTM) was lower and lean tissue mass (LTM) higher in the prone measurements. When the head was excluded, the mean FTM difference between the two measurements became greater (FTM supine v prone, 25.129+/-10.445 v 24.030+/-10.388 kg, P=.0001; LTM supine v prone, 37.309+/-9.357 v 38.246+/-9.150 kg, P=.0001). It is concluded that the positioning of the patient on the examination table affects DEXA body composition measurements by the fan-beam mode. This could imply a lack of accuracy of the method, which may be due to subtle changes in regional tissue depth and fat distribution caused by patient repositioning.

Entities:  

Mesh:

Year:  1998        PMID: 9826217     DOI: 10.1016/s0026-0495(98)90309-2

Source DB:  PubMed          Journal:  Metabolism        ISSN: 0026-0495            Impact factor:   8.694


  2 in total

1.  Accuracy and Reliability of Assessing Lateral Compartmental Leg Composition Using Dual-Energy X-ray Absorptiometry.

Authors:  Christiana J Raymond; Tyler A Bosch; Foster K Bush; Lisa S Chow; Donald R Dengel
Journal:  Med Sci Sports Exerc       Date:  2017-04       Impact factor: 5.411

2.  Evaluation of dual-energy X-ray absorptiometry compared to magnetic resonance imaging for collecting measurements of the human bony pelvis.

Authors:  Sarah-Louise Decrausaz; Meghan K Shirley; Jay T Stock; Jane E Williams; Mary S Fewtrell; Chris A Clark; Owen J Arthurs; Jonathan C K Wells
Journal:  Am J Hum Biol       Date:  2022-04-23       Impact factor: 2.947

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.