Literature DB >> 9825561

A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures.

S Thomas1, M Sherriff, D Birnie.   

Abstract

The aim of this in vitro study was to investigate the frictional characteristics of two types of self-ligating brackets ('A' Company Damon SL and Adenta Time brackets) and two types of pre-adjusted edgewise brackets (TP Tip-Edge and 'A' Company Standard Twin brackets). The test brackets were glued to steel bars and aligned using a preformed jig. Five combinations of archwire size and material were used (0.014-inch nickel titanium, 0.0175-inch multistrand stainless steel, 0.016 x 0.022-inch nickel titanium, 0.016 x 0.022-inch stainless steel and 0.019 x 0.025-inch stainless steel wires). The wires were drawn through the brackets and the frictional resistance was measured using an Instron 1193 testing machine. The data were analysed using a one-way analysis of variance and Scheffe's multiple comparison of means test. The results revealed that the Damon brackets demonstrated the lowest friction for all dimensions of test wires followed by the Time bracket. The 'A' Company Standard Twin brackets produced the highest friction with all wire dimensions tested, followed by the Tip-Edge bracket. With all brackets the 0.016 x 0.022-inch nickel titanium wires produced a higher frictional resistance than the 0.016 x 0.022-inch stainless steel wires. The results indicate that these self-ligating brackets produce less frictional resistance than elastomerically-tied pre-adjusted edgewise brackets.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9825561     DOI: 10.1093/ejo/20.5.589

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  25 in total

1.  Comparative evaluation of anchorage loss between self-ligating appliance and Conventional pre-adjusted edgewise appliance using sliding mechanics - A retrospective study.

Authors:  Pankaj Juneja; G Shivaprakash; S S Chopra; P B Kambalyal
Journal:  Med J Armed Forces India       Date:  2014-04-03

2.  Friction in a hybrid system. An in vitro study.

Authors:  M Rozzi; M Mucedero; L Franchi; P Cozza
Journal:  Oral Implantol (Rome)       Date:  2011-01-23

3.  Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

Authors:  Sujeet Kumar; Shamsher Singh; Rani Hamsa P R; Sameer Ahmed; Apoorva Bhatnagar; Manreet Sidhu; Pramod Shetty
Journal:  J Clin Diagn Res       Date:  2014-05-15

4.  Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

Authors:  Vanessa Vieira Leite; Murilo Baena Lopes; Alcides Gonini Júnior; Marcio Rodrigues de Almeida; Sandra Kiss Moura; Renato Rodrigues de Almeida
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

Review 5.  Systematic review on self-ligating vs. conventional brackets: initial pain, number of visits, treatment time.

Authors:  Ales Čelar; Magdalena Schedlberger; Petra Dörfler; Michael Bertl
Journal:  J Orofac Orthop       Date:  2013-01-10       Impact factor: 1.938

6.  The leveling effectiveness of self-ligating and conventional brackets for complex tooth malalignments.

Authors:  Magali Fansa; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

7.  Corrosion behavior of self-ligating and conventional metal brackets.

Authors:  Lúcio Henrique Esmeraldo Gurgel Maia; Hibernon Lopes Filho; Antônio Carlos de Oliveira Ruellas; Mônica Tirre de Souza Araújo; Delmo Santiago Vaitsman
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr

8.  Evaluation of the friction of self-ligating and conventional bracket systems.

Authors:  Simona Tecco; Donato Di Iorio; Riccardo Nucera; Beatrice Di Bisceglie; Giancarlo Cordasco; Felice Festa
Journal:  Eur J Dent       Date:  2011-07

9.  Role of lubricants on friction between self-ligating brackets and archwires.

Authors:  Renata C Leal; Flávia L B Amaral; Fabiana M G França; Roberta T Basting; Cecilia P Turssi
Journal:  Angle Orthod       Date:  2014-04-01       Impact factor: 2.079

10.  In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment.

Authors:  Giancarlo Cordasco; Antonino Lo Giudice; Angela Militi; Riccardo Nucera; Giuseppe Triolo; Giovanni Matarese
Journal:  Korean J Orthod       Date:  2012-08-28       Impact factor: 1.372

View more