Evaluation of a dual sensor rate responsive pacing system based on a new concept. French Talent DR Pacemaker Investigators.

J L Bonnet1, L Géroux, S Cazeau.   

Abstract

The minute ventilation is known to be one of the most physiological indicators of exercise. A curvilinear relationship between VE and the normal sinus rhythm (NSR) has been demonstrated in healthy patients. The aim of this study is to show that a pacemaker based on a VE sensor can reproduce such a relationship. Eighty-one patients received a Talent DR 213 (ELA Medical, Montrouge, France) pacemaker with a third-generation rate responsive algorithm. At 1-month follow-up, the patients underwent a treadmill exercise test, after which three groups were defined: group 1 had 6 patients who were 100% paced throughout the exercise test; group 2 had 10 patients who maintained NSR throughout the test; and group 3 had 12 patients who had cardiopulmonary recording during the exercise test. In group 1 patients, the simulation function computed the simulated rate (sim-rate), which was compared to the sensor-driven rate (SDR). In group 2 patients, sim-rate was compared to the NSR. In group 3 patients, cardiac and metabolic reserves were compared to determine the appropriateness of the rate response to exercise (HRR% vs MR%). The results showed that the mean correlation coefficient between sim-rate and SDR was 0.983 +/- 0.005 (P < 0.001); the mean correlation coefficient between NSR and SDR was 0.92 +/- 0.07 (P < 0.001); and a linear relationship was found between HRR% and MR%, with a mean slope of 1.1 +/- 0.2 that was significantly equal to the theoretical value of 1 (P = NS). In conclusion, combining an activity-driven sensor with a physiological sensor allows the preservation of a physiological rate response during exercise.

Entities:  

Mesh:

Year:  1998        PMID: 9825318     DOI: 10.1111/j.1540-8159.1998.tb01152.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Non-physiological increase of AV conduction time in sinus disease patients programmed in AAIR-based pacing mode.

Authors:  Philippe Mabo; Jean-Pierre Cebron; Aude Solnon; Aude Tassin; Laurence Graindorge; Daniel Gras
Journal:  J Interv Card Electrophysiol       Date:  2012-07-27       Impact factor: 1.900

2.  Assessment of adaptive rate response provided by accelerometer, minute ventilation and dual sensor compared with normal sinus rhythm during exercise: a self-controlled study in chronotropically competent subjects.

Authors:  Yuanyuan Cao; Yiqun Zhang; Yangang Su; Jin Bai; Wei Wang; Junbo Ge
Journal:  Chin Med J (Engl)       Date:  2015-01-05       Impact factor: 2.628

3.  The future of telemedicine for the management of heart failure patients: a Consensus Document of the Italian Association of Hospital Cardiologists (A.N.M.C.O), the Italian Society of Cardiology (S.I.C.) and the Italian Society for Telemedicine and eHealth (Digital S.I.T.).

Authors:  Andrea Di Lenarda; Giancarlo Casolo; Michele Massimo Gulizia; Nadia Aspromonte; Simonetta Scalvini; Andrea Mortara; Gianfranco Alunni; Renato Pietro Ricci; Roberto Mantovan; Giancarmine Russo; Gian Franco Gensini; Francesco Romeo
Journal:  Eur Heart J Suppl       Date:  2017-05-02       Impact factor: 1.803