Literature DB >> 9824002

The accuracy and interobserver agreement in detecting the 'gallop sounds' by cardiac auscultation.

C E Lok1, C D Morgan, N Ranganathan.   

Abstract

STUDY
OBJECTIVES: To determine the observer accuracy and interobserver agreement in identifying S4 and S3 by cardiac auscultation and whether they improve with increasing observer experience.
DESIGN: Prospective, blinded study.
SETTING: Cardiology and general internal medicine wards in a university-affiliated teaching hospital. PATIENTS: Forty patients with a cardiac diagnosis and 6 patients without were studied. MEASUREMENTS AND
RESULTS: Two cardiologists, one general internist, three senior and two junior postgraduate internal medicine trainees, blinded to the patients' characteristics, examined the patients and documented their findings on a questionnaire. Computerized phonocardiogram was obtained in all patients as a gold standard and was interpreted by a blinded, independent cardiologist. The mean positive predictive values for S4 and S3 were 51% (range, 24 to 100%) and 71% (range, 50 to 88%), respectively. The mean negative predictive values for S4 and S3 were 82% (range, 67 to 94%) and 64% (range, 56 to 85%), respectively. The overall interobserver agreements for detecting S4 was K = 0.05 (95% confidence interval [CI], 0.01 to 0.09) and S3 was K = 0.18 (95% CI, 0.13 to 0.24). There was no apparent trend in the accuracy or interobserver agreement with regard to the level of observer experience.
CONCLUSION: The agreement between observers and the phonocardiographic gold standard in the correct identification of S4 and S3 was poor and the lack of agreement did not appear to be a function of the experience of the observers. The overall interobserver agreement for the detection of either S4 or S3 was little better than chance alone.

Entities:  

Mesh:

Year:  1998        PMID: 9824002     DOI: 10.1378/chest.114.5.1283

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  19 in total

1.  Using a multimedia tool to improve cardiac auscultation knowledge and skills.

Authors:  D T Stern; R S Mangrulkar; L D Gruppen; A L Lang; C M Grum; R D Judge
Journal:  J Gen Intern Med       Date:  2001-11       Impact factor: 5.128

2.  Ultrasound stethoscopy: a renaissance of the physical examination?

Authors:  J R T C Roelandt
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

Review 3.  Echocardiography: frontier imaging in cardiology.

Authors:  R P Steeds
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

4.  Simulation-guided cardiac auscultation improves medical students' clinical skills: the Pavia pilot experience.

Authors:  Stefano Perlini; Francesco Salinaro; Paola Santalucia; Francesco Musca
Journal:  Intern Emerg Med       Date:  2012-07-06       Impact factor: 3.397

5.  Relationship between accurate auscultation of the fourth heart sound and the level of physician experience.

Authors:  Saurabh Gupta; Andrew D Michaels
Journal:  Clin Cardiol       Date:  2009-02       Impact factor: 2.882

6.  Interobserver reliability of urine sediment interpretation.

Authors:  Ron Wald; Chaim M Bell; Rosane Nisenbaum; Samuel Perrone; Orfeas Liangos; Andreas Laupacis; Bertrand L Jaber
Journal:  Clin J Am Soc Nephrol       Date:  2009-03-04       Impact factor: 8.237

Review 7.  The third heart sound for diagnosis of acute heart failure.

Authors:  Michael Johnston; Sean P Collins; Alan B Storrow
Journal:  Curr Heart Fail Rep       Date:  2007-09

8.  Sequence of electrocardiographic and acoustic cardiographic changes and angina during coronary occlusion and reperfusion in patients undergoing percutaneous coronary intervention.

Authors:  Eunyoung Lee; Barbara J Drew; Ronald H Selvester; Andrew D Michaels
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-04       Impact factor: 1.468

Review 9.  Ultrasound imaging of congestion in heart failure: examinations beyond the heart.

Authors:  Pierpaolo Pellicori; Elke Platz; Jeroen Dauw; Jozine M Ter Maaten; Pieter Martens; Emanuele Pivetta; John G F Cleland; John J V McMurray; Wilfried Mullens; Scott D Solomon; Faiez Zannad; Luna Gargani; Nicolas Girerd
Journal:  Eur J Heart Fail       Date:  2020-11-23       Impact factor: 15.534

10.  Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study.

Authors:  Maurizio Galderisi; Alessandro Santoro; Marco Versiero; Vincenzo Schiano Lomoriello; Roberta Esposito; Rosa Raia; Francesca Farina; Pier Luigi Schiattarella; Manuela Bonito; Marinella Olibet; Giovanni de Simone
Journal:  Cardiovasc Ultrasound       Date:  2010-11-26       Impact factor: 2.062

View more