Abstract

The aim of this study was to determine the shaping ability of ProFile 0.04 taper rotary nickel-titanium instruments with ISO sized tips in simulated canals. A total of 40 simulated root canal made up of four different shapes in terms of angle and position of curvature were prepared by ProFile instruments using the 'crown down' approach recommended by the manufacturer. Part 1 of this two-part report describes the efficacy of the instruments in terms of preparation time, instrument failure, canal blockages, loss of canal length and three-dimensional canal form. The time necessary for canal preparation was on average 5.2 min and was not influenced significantly by canal shape. Three instrument fractures occurred and a further 3 instruments deformed; size 35 instruments failed the most (4) followed by size 30 (2), four of the failures occurred in canals with 40 degrees curves. None of the canals became blocked with debris and change in working distance was minimal. Intra-canal impressions of canal form demonstrated that most canals had apical stops and smooth canal walls whereas all canals had good flow and taper. Under the conditions of this study, ProFile 0.04 taper rotary nickel-titanium instruments with ISO sized tips prepared simulated canals rapidly and created good three-dimensional form.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9823117     DOI: 10.1046/j.1365-2591.1998.00153.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  13 in total

1.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

2.  Cutting efficiency of four different rotary nickel: Titanium instruments.

Authors:  Doglas Cecchin; Manoel Damião de Sousa-Neto; Jesus Djalma Pécora; Ricardo Gariba-Silva
Journal:  J Conserv Dent       Date:  2011-04

3.  Evaluation of surface preparation and maintenance of canal curvature following instrumentation with hand 'K' file and three different Ni-Ti rotary systems: A radiographic and SEM study.

Authors:  Namrata Bhatti; Renu Sroa; Vimal K Sikri
Journal:  Contemp Clin Dent       Date:  2010-04

4.  Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System.

Authors:  Seyed Mohsen Hasheminia; Nastaran Farhadi; Ali Shokraneh
Journal:  ISRN Dent       Date:  2013-09-12

Review 5.  Single file reciprocating systems: A systematic review and meta-analysis of the literature: Comparison of reciproc and WaveOne.

Authors:  Rana Alsilani; Fatima Jadu; Dania F Bogari; Ahmed M Jan; Turki Y Alhazzazi
Journal:  J Int Soc Prev Community Dent       Date:  2016-10-24

6.  Cervical Dentin Changes in Curved Root Canals after Using WaveOne and Reciproc Files with Full Rotation versus Reciprocation Movement: An Ex vivo Study.

Authors:  Yazdan Shantiaee; Golnaz Nahvi; Omid Dianat; Farzad Aghdashi
Journal:  Contemp Clin Dent       Date:  2017 Jul-Sep

7.  The effect of root canal preparation on the development of dentin cracks.

Authors:  Amin Salem Milani; Mohammad Froughreyhani; Saeed Rahimi; Mohammad Asghari Jafarabadi; Sara Paksefat
Journal:  Iran Endod J       Date:  2012-10-13

8.  Working length changes in curved canals after coronal flaring by using rotary files and hand file: An in vitro study.

Authors:  Rahul Kumar; Neha Khambete; Suvarna Patil; Upendra Hoshing; Ashish Medha; Roshan Shetty
Journal:  J Conserv Dent       Date:  2013-09

9.  The Efficacy of FlexMaster's IntroFile, PreRaCe and Gates Glidden Drills in Straight-Line Access: A CBCT Assessment.

Authors:  Narges Farhad Mollashahi; Mahdi Sohrabi; Leila Farhad Mollashahi; Mojdeh Mehdizadeh
Journal:  Iran Endod J       Date:  2014-07-05

Review 10.  Comparison of cleaning Efficacy and Instrumentation Time between Rotary and Manual Instrumentation Techniques in Primary Teeth: An in vitro Study.

Authors:  Farhin Katge; Vamsi Krishna Chimata; Manohar Poojari; Shilpa Shetty; Bhavesh Rusawat
Journal:  Int J Clin Pediatr Dent       Date:  2016-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.