Literature DB >> 9820910

The vertebral body depths of the cervical spine and its relation to anterior plate-screw fixation.

N A Ebraheim1, J Fow, R Xu, R A Yeasting.   

Abstract

STUDY
DESIGN: A study was performed to measure the vertebral body depths in different locations from C2 to C7.
OBJECTIVES: To measure the vertebral body depths in 10 linear dimension from C2 to C7. SUMMARY OF BACKGROUND DATA: Anterior plate-screw fixation of the cervical spine has been the common surgical procedure for management of multilevel degenerative disc disease and fracture dislocation. However, injury to the spinal cord during drill or screw placement is the most feared complication of this procedure. It is beneficial for one to have a knowledge of the vertebral body depths in different locations of the vertebral body before anterior cervical plating.
METHODS: Twenty-seven cervical spines from C2 to C7 were evaluated directly for this study. Anatomic evaluation of the vertebral body included the anteroposterior midline sagittal depth and the anteroposterior parasagittal depth 5 mm lateral to midline on the superior and inferior endplates, as well as on the middle body. Measurements also were made of anteroposterior parasagittal vertebral depth with both medial and lateral inclination of 10 degrees, with respect to the parasagittal plane of the vertebral body.
RESULTS: In general, the measurements of male specimens were larger than those of female specimens. Significant differences were noted at 21 measurements over C3 through C7. The mean depths of the superior endplate for all male and female specimens increased consistently from C3 to C7. The mean depths of the inferior endplate varied but generally increased from C2 to C6, then decreased to C7. The mean sagittal and parasagittal middle vertebral body depths were both 14 mm.
CONCLUSIONS: This information, in conjunction with preoperative computed tomographic evaluation, may be helpful in determining proper screw length during anterior plating of the cervical spine.

Entities:  

Mesh:

Year:  1998        PMID: 9820910     DOI: 10.1097/00007632-199811010-00010

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  4 in total

1.  The cervical spine and its relation to anterior plate-screw fixation: a quantitative study.

Authors:  Sven R Kantelhardt; Joachim Oberle; Sharam Derakhshani; Erich Kast
Journal:  Neurosurg Rev       Date:  2005-04-05       Impact factor: 3.042

2.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

3.  Anatomic basis of anterior and posterior instrumentation of the spine: morphometric study.

Authors:  Bashar Abuzayed; Banu Tutunculer; Baris Kucukyuruk; Saffet Tuzgen
Journal:  Surg Radiol Anat       Date:  2009-08-21       Impact factor: 1.246

4.  Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models.

Authors:  Long Wang; Hao T Luo; Wei Lu; Xing Bo Cai; Chen Yu; Sheng Lu
Journal:  J Orthop Surg Res       Date:  2021-08-16       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.