Literature DB >> 9820612

Experience with the Biostator for diagnosis and assisted surgery of 21 insulinomas.

H Gin1, B Catargi, V Rigalleau, E Rullier, P Roger, A Tabarin.   

Abstract

Surgical removal is the treatment of choice for insulinomas. Definitive biochemical diagnosis of organic hyperinsulinism has to be established before surgery. These tumors are sometimes undetected by preoperative imaging investigations and, in addition, surgical management may also be complicated by the absence of palpable tumors or the presence of multiple tumors. We report the value of the euglycemic clamp technique for diagnosis and surgical treatment in 21 patients with confirmed insulinomas. Data were compared with 12 controls, and nine patients were retested after surgery. During the euglycemic hyperinsulinic clamp, the mean C-peptide value was 3.6+/-2.2 ng/ml and it remained high (3.8+/-2.5 ng/ml), despite exogenous hyperinsulinemia (1762.7+/-233.2 microU/ml for the highest plateau). In contrast, the C-peptide concentration declined in 12 control patients (0.3+/-0.1 ng/ml, P < 0.001) and after successful surgery in nine retested patients (0.3+/-0.2 ng/ml, P < 0.01). During continuous glucose monitoring, successful removal of the insulin-secreting tumor was accompanied by an increase in plasma glucose concentrations and a loss of requirement for endogenous glucose within 36 min (range 28-43 min). The continuing requirement for glucose after the ablation of the tumor revealed the existence of additional and initially undetected tumors in four patients, among whom two had the multiple endocrine neoplasia type I (MEN I) syndrome. We conclude that the euglycemic hyperinsulinic clamp is a reliable and convenient diagnostic test for insulinoma, as it is both safe (no hypoglycemia) and relatively brief (3 x 90 min). Glucose monitoring and glucose clamping provide a reliable indicator of complete removal of insulin-hypersecreting tissue, especially in patients with occult or multiple tumors.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9820612     DOI: 10.1530/eje.0.1390371

Source DB:  PubMed          Journal:  Eur J Endocrinol        ISSN: 0804-4643            Impact factor:   6.664


  4 in total

1.  Social behavioural epistemology and the scientific community.

Authors:  Milind Watve
Journal:  J Genet       Date:  2017-07       Impact factor: 1.166

Review 2.  Clinical need for continuous glucose monitoring in the hospital.

Authors:  Jeffrey I Joseph; Brian Hipszer; Boris Mraovic; Inna Chervoneva; Mark Joseph; Zvi Grunwald
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

Review 3.  Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.

Authors:  Jeffrey I Joseph; Marc C Torjman; Paul J Strasma
Journal:  J Diabetes Sci Technol       Date:  2015-06-15

4.  The artificial pancreas: how sweet engineering will solve bitter problems.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2007-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.