Literature DB >> 9820211

Subcutaneous administration of midazolam: a comparison of the Bioject jet injector with the conventional syringe and needle.

J Bennett1, F Nichols, M Rosenblum, J Condry.   

Abstract

PURPOSE: The purpose of this study was to compare jet injection to a syringe and needle in terms of the difference in discomfort and pharmacokinetics after the subcutaneous administration of midazolam. PATIENTS AND METHODS: Using a prospective, randomized, double-blinded study design, 14 subjects were administered midazolam on two separate occasions (at least 2 weeks apart). The subjects were randomly distributed into two groups: syringe and needle (saline)/jet injector (midazolam) or syringe and needle (midazolam)/jet injector (saline). The subjects were randomly assigned to receive either EMLA (eutectic mixture of local anesthetics) or a placebo at the injection site for the first administration and the other topical agent on the second visit. Each subject received one subcutaneous injection in the deltoid region per arm per day. Each injection contained the same volume of solution. Subjects completed visual analog scale (VAS) questionnaires assessing the discomfort of the injection. Blood samples were taken at specified intervals over 2 hours for determination of midazolam levels.
RESULTS: The discomfort associated with the injection was less with the Biojector 2000 (Bioject Inc, Portland, OR) although this was not statistically significant. However, persistent discomfort was significantly greater at the needle site. The mean peak plasma level of midazolam was achieved more rapidly with the Biojector 2000 than with the syringe and needle (P < .05). However, the peak plasma level after jet injection or injection with a syringe and needle was not statistically different.
CONCLUSION: The results of the study show that the Biojector 2000 is a needle-free injection system that can be used for the administration of a premedicant before induction of anesthesia. It has several advantages, including the potential reduction of anxiety associated with the "fear of needles" and occupational injuries.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9820211     DOI: 10.1016/s0278-2391(98)90601-2

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  4 in total

Review 1.  'Needle-free' delivery of local anesthesia: a valuable option in pediatrics.

Authors:  William M Splinter
Journal:  Paediatr Drugs       Date:  2002       Impact factor: 3.022

2.  Posterior segment injury developed after injection of anesthetics on eyelids with needleless jet injection device.

Authors:  Ji Eun Lee; Hee Young Choi; Jong Soo Lee; Boo Sup Oum
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-04-22       Impact factor: 3.117

3.  Absolute bioavailability of midazolam after subcutaneous administration to healthy volunteers.

Authors:  M Pecking; F Montestruc; P Marquet; E Wodey; M-C Homery; P Dostert
Journal:  Br J Clin Pharmacol       Date:  2002-10       Impact factor: 4.335

4.  Intravenous versus Subcutaneous Midazolam Using Jet-injector in Pediatric Sedation; a Randomized Clinical Trial.

Authors:  Majid Hajimaghsoudi; Mehdi Bagherabadi; Ehsan Zarepur; Vahid Ahmadi Hanzaei
Journal:  Emerg (Tehran)       Date:  2018-08-31
  4 in total