Positive end-expiratory pressure improves gas exchange and pulmonary mechanics during partial liquid ventilation.

M Kirmse1, Y Fujino, D Hess, R M Kacmarek.   

Abstract

Partial liquid ventilation (PLV) with perflubron (PFB) has been proposed as an adjunct to the current therapies for the acute respiratory distress syndrome (ARDS). Because PFB has been also referred to as "liquid PEEP," distributing to the most gravity-dependent regions of the lung, less attention has been paid to the amount of applied positive end-expiratory pressure (PEEP). We hypothesized that higher PEEP levels than currently applied are needed to optimize gas exchange, and that the lower inflection point (LIP) of the pressure-volume curve could be used to estimate the amount of PEEP needed when the lung is filled with PFB. Lung injury was induced in 23 sheep by repeated lung lavage with warmed saline until the PaO2/FIO2 ratio fell below 150. Five sheep were used to investigate the change of the LIP when the lung was filled with PFB in increments of 5 ml/kg/body weight to a total of 30 ml/kg/body weight. To evaluate the impact of PEEP set at LIP +1 cm H2O we randomized an additional 15 sheep to three groups with different doses (7.5 ml, 15 ml, 30 ml/kg/body weight) of PFB. In random order a PEEP of 5 cm H2O or PEEP at LIP +1 cm H2O was applied. The LIP decreased with incremental filling of PFB to a minimum at 10 ml (p < 0.05). Increasing PEEP from below LIP to LIP +1 cm H2O at 15 and 30 ml/kg resulted in an improvement in PaO2 from 152 +/- 36 to 203 +/- 68 (NS) and 193 +/- 57 to 298 +/- 80 (p < 0.05), respectively. Pulmonary shunt, and ratio of dead space volume to tidal volume (VD/VT) decreased, and static lung compliance increased with PEEP at LIP +1 cm H2O (p < 0.05). No changes were observed in hemodynamics. We conclude that increasing the dose of PFB shifts the LIP to the left, and that setting PEEP at LIP +1 cm H2O improves gas exchange at moderate to high doses of PFB.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9817707     DOI: 10.1164/ajrccm.158.5.9708100

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  4 in total

Review 1.  High-frequency oscillatory ventilation: what large-animal studies have taught us!

Authors:  Robert M Kacmarek; Atul Malhotra
Journal:  Crit Care Med       Date:  2005-03       Impact factor: 7.598

2.  The Implantable Pediatric Artificial Lung: Interim Report on the Development of an End-Stage Lung Failure Model.

Authors:  Fares Alghanem; Ryan P Davis; Benjamin S Bryner; Hayley R Hoffman; John Trahanas; Marie S Cornell; Alvaro Rojas-Peña; Robert H Bartlett; Ronald B Hirschl
Journal:  ASAIO J       Date:  2015 Jul-Aug       Impact factor: 2.872

3.  Partial liquid ventilation: effects of positive end-expiratory pressure on perfluorocarbon evaporation from the lungs of anesthetized dogs.

Authors:  Stephan A Loer; Lothar A Schwarte; Michael A Pakulla; Olaf Picker; Thomas W L Scheeren
Journal:  Intensive Care Med       Date:  2003-02-08       Impact factor: 17.440

4.  Effect of partial liquid ventilation on bacterial clearance during Pseudomonas aeruginosa-induced lung injury in rats.

Authors:  Saïda Rezaiguia-Delclaux; Kun Yang; François Stephan; François Lemaire; Michel Meignan; Alain Harf; Philippe Duvaldestin; Christophe Delclaux
Journal:  Intensive Care Med       Date:  2003-05-24       Impact factor: 17.440

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.