Pitfalls in processing home electronic spirometric data in asthma.

H K Reddel1, S I Ware, C M Salome, C R Jenkins, A J Woolcock.   

Abstract

Electronic spirometers offer the prospect of paperless home monitoring, but data quality is not automatically better than from conventional monitoring. The aim of this study was to determine the extent to which the quality and processing of self-recorded spirometric data from patients with asthma complied with international guidelines for spirometry. Data were from 33 subjects with poorly controlled asthma who had completed the first 9 weeks of a clinical budesonide trial. MicroMedical DiaryCard electronic spirometers were used to record three spirometric manoeuvres in twice-daily sessions. Confounding events were recorded in a paper diary. Within-session reproducibility was calculated for forced expiratory volume in one second (FEV1), forced vital capacity (FVC) and peak expiratory flow (PEF) during the first week of run-in and week 9 of budesonide treatment. Geometric means of within-session reproducibility (mean difference between highest and second-highest value from each session over a one-week period) for FEV1, FVC and PEF were 76 mL, 116 mL and 18 L x min(-1), respectively, during run-in. Times of spirometric sessions varied widely, with some overlap between morning and evening session times. Manoeuvre-induced falls in PEF and FEV1 occurred only as often as expected by chance. Nonasthma events including equipment faults and painful conditions caused changes in spirometric results. Home spirometric monitoring can be carried out with excellent reproducibility in patients with asthma. However, quality-control issues are complex and an accompanying paper diary remains essential.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9817158     DOI: 10.1183/09031936.98.12040853

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  8 in total

1.  Diurnal variability--time to change asthma guidelines?

Authors:  H Reddel; C Jenkins; A Woolcock
Journal:  BMJ       Date:  1999-07-03

2.  Analysis of adherence to peak flow monitoring when recording of data is electronic.

Authors:  Helen K Reddel; Brett G Toelle; Guy B Marks; Sandra I Ware; Christine R Jenkins; Ann J Woolcock
Journal:  BMJ       Date:  2002-01-19

3.  When can personal best peak flow be determined for asthma action plans?

Authors:  H K Reddel; G B Marks; C R Jenkins
Journal:  Thorax       Date:  2004-11       Impact factor: 9.139

Review 4.  Measures of asthma control.

Authors:  Christian Bime; Jessica Nguyen; Robert A Wise
Journal:  Curr Opin Pulm Med       Date:  2012-01       Impact factor: 3.155

5.  Evaluation of a novel method to assess corticosteroid responsiveness in chronic obstructive pulmonary disease.

Authors:  Fahad A Al-Ghimlas; Andrew McIvor
Journal:  Ann Thorac Med       Date:  2010-10       Impact factor: 2.219

Review 6.  Difficult vs. Severe Asthma: Definition and Limits of Asthma Control in the Pediatric Population.

Authors:  Amelia Licari; Ilaria Brambilla; Alessia Marseglia; Maria De Filippo; Valeria Paganelli; Gian L Marseglia
Journal:  Front Pediatr       Date:  2018-06-19       Impact factor: 3.418

7.  A comparison of peak expiratory flow measured from forced vital capacity and peak flow meter manoeuvres in healthy volunteers.

Authors:  Dipti Agarwal; Prem Parkash Gupta
Journal:  Ann Thorac Med       Date:  2007-07       Impact factor: 2.219

Review 8.  Telehealthcare for asthma.

Authors:  Susannah McLean; David Chandler; Ulugbek Nurmatov; Joseph Liu; Claudia Pagliari; Josip Car; Aziz Sheikh
Journal:  Cochrane Database Syst Rev       Date:  2010-10-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.