Literature DB >> 9814930

The effect of intraarticular anesthesia and elastic bandage on elbow proprioception.

V Khabie1, M C Schwartz, A S Rokito, M A Gallagher, F Cuomo, J D Zuckerman.   

Abstract

Twenty uninjured male volunteers were studied to characterize normal elbow proprioception and to investigate the effect of applying an elastic bandage to the extremity and injection of an intraarticular anesthetic. A modified Biodex dynamometer was used to study position sense and detection of motion. In part 1 of the study position sense was tested by flexing the elbow to a predetermined angle, returning to the starting position, and then asking the subject to identify that angle. In part 2 detection of motion was tested by asking the subject to disengage the apparatus by pressing a stop button when movement was detected. The testing conditions in part 1 and part 2 were repeated after the elbow was wrapped with an elastic bandage and again after an intraarticular injection of 3 cc 1% lidocaine with the bandage removed. Ten additional subjects underwent testing of both elbows to examine the effect of arm dominance. Mean position sense was within 3.3 degrees+/-1.3 degrees of the actual angle in trials without an elastic bandage or an anesthetic. A significant improvement in position sense was observed (2.2 degrees+/-1.2 degrees) after an elastic bandage was applied (P < .004). No significant difference was seen in position sense after lidocaine was injected. The mean threshold for detection of motion in trials without an elastic bandage or an anesthetic was 4.21 degrees+/-1.56 degrees. No significant differences were seen in detection of motion observed with the elastic bandage or intraarticular anesthetic. No significant differences were seen between dominant and nondominant extremities for both position sense and detection of motion. The application of an elastic bandage improved position sense, suggesting that tactile cues from cutaneous or other extraarticular receptors may play a role in elbow proprioception. Intraarticular anesthesia, however, had little effect, suggesting that intracapsular receptors play a lesser role in elbow proprioception. The determination of proprioceptive qualities for the normal elbow can aid in the understanding of elbow function and provide a basis for defining its role in elbow dysfunction.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9814930     DOI: 10.1016/s1058-2746(98)90202-6

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  5 in total

1.  Intra-articular anesthesia and knee muscle response.

Authors:  Heidi L Oksendahl; Braden C Fleming; Peter R Blanpied; Mark Ritter; Michael J Hulstyn; Paul D Fadale
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-03-12       Impact factor: 2.063

2.  The Effect of a Neoprene Shoulder Stabilizer on Active Joint-Reposition Sense in Subjects With Stable and Unstable Shoulders.

Authors:  Jennifer C Chu; Edward J Kane; Brent L Arnold; Bruce M Gansneder
Journal:  J Athl Train       Date:  2002-06       Impact factor: 2.860

3.  Effects of local anesthetics on somatosensory function in the temporomandibular joint area.

Authors:  Emad E Ayesh; Malin Ernberg; Peter Svensson
Journal:  Exp Brain Res       Date:  2007-02-15       Impact factor: 1.972

4.  Elbow joint active replication in college pitchers following simulated game throwing: an exploratory study.

Authors:  Robert Manske; Mark Stovak; Kara Cox; Barbara Smith
Journal:  Sports Health       Date:  2010-07       Impact factor: 3.843

5.  Shoulder proprioception following reverse total shoulder arthroplasty.

Authors:  Joanna Walecka; Przemysław Lubiatowski; Paolo Consigliere; Ehud Atoun; Ofer Levy
Journal:  Int Orthop       Date:  2020-08-15       Impact factor: 3.075

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.