Literature DB >> 9811506

Physical stress testing of insulin suspensions and solutions.

D R Shnek1, D L Hostettler, M A Bell, J M Olinger, B H Frank.   

Abstract

Insulin pen-cartridge devices have evolved in order to increase patient compliance and convenience of use in a portable, multiple dosage device. With the advent of a portable insulin containing device, stability considerations have evolved from standard chemical indicators to include the effects of temperature and agitation on physical characteristics. To address these issues, two automated physical stress tests were developed based on market research data and input from regulatory authorities to understand the effect of thermomechanical stress on the product. First, the temperature cycling and resuspension test (TCRT) includes temperature cycling (25-37 degreesC) combined with agitation. The high temperature and extreme agitation test (HTEAT) includes continuous high temperature (37 degreesC) exposure combined with 4 h daily agitation. The total stress exposure is a function of the temperature, agitation, and time. The tests range from moderate stress (TCRT) to considerable stress (HTEAT) determined from the number of cartridge inversions and average daily temperature. Physical stress testing of both insulin suspensions and solution formulations in cartridges were performed and interpreted with respect to multiple endpoints. For suspensions, prolonged exposure to extreme stress caused the protein to form agglomerates, either in the suspension or adhered to the cartridge walls. In contrast, protein solutions subjected to the same extreme stress conditions did not exhibit any visually detectable change. Visual changes in the product under physical stress conditions can increase dose-potency result variability as well as exhibit acid-insoluble aggregates.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9811506     DOI: 10.1021/js980074x

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  4 in total

1.  Characterizing normal-use temperature conditions of pumped insulin.

Authors:  Joshua K Herr; Steven Keith; Rick Klug; Ronald J Pettis
Journal:  J Diabetes Sci Technol       Date:  2014-05-12

Review 2.  Insulin Formulation Characterization-the Thioflavin T Assays.

Authors:  Morten Schlein
Journal:  AAPS J       Date:  2016-12-20       Impact factor: 4.009

Review 3.  EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management.

Authors:  Silver Bahendeka; Ramaiya Kaushik; Andrew Babu Swai; Fredrick Otieno; Sarita Bajaj; Sanjay Kalra; Charlotte M Bavuma; Claudine Karigire
Journal:  Diabetes Ther       Date:  2019-02-27       Impact factor: 2.945

4.  Heat-stability study of various insulin types in tropical temperature conditions: New insights towards improving diabetes care.

Authors:  Beatrice Kaufmann; Philippa Boulle; Flavien Berthou; Margot Fournier; David Beran; Iza Ciglenecki; Malcolm Townsend; Guillaume Schmidt; Maya Shah; Susanna Cristofani; Philippe Cavailler; Michelangelo Foti; Leonardo Scapozza
Journal:  PLoS One       Date:  2021-02-03       Impact factor: 3.240