Literature DB >> 9811142

Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence.

A J Freeman1, P A Gowland, P Mansfield.   

Abstract

The Look-Locker echo-planar imaging (LL-EPI) sequence has been numerically optimized in terms of the signal-to-noise ratio in the measured value of T1, for both single-shot (repetition time (TR) = infinity), and dynamically repeated T1 measurements. The sequence is optimized for the normal biologic range of T1 (0.2 s to 2.0 s) and for a range of sequence parameters found on most magnetic resonance (MR) scanners. Both linearly and geometrically spaced magnetization sample pulse intervals were considered. For single-shot measurements, the sequence with 24 linearly spaced sample pulses, an inversion time of 0.01 s, an inter-sample pulse delay of 0.10 s, and a sample radiofrequency (RF) pulse flip angle of 25 degrees was found to be optimum. When the number of sample pulses was limited due to hardware limitations, different pulse sequence parameters were indicated. The optimization procedures used are appropriate for any single-shot T1 mapping sequence variant and for any rapid T1 mapping application. The use of an optimized Look-Locker echo-planar imaging sequence is demonstrated by an example of dynamic contrast-enhanced scanning in the brain using fast T1 mapping.

Mesh:

Substances:

Year:  1998        PMID: 9811142     DOI: 10.1016/s0730-725x(98)00011-3

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  17 in total

Review 1.  Quantitative MR Imaging of Brain Tissue and Brain Pathologies.

Authors:  E Hattingen; A Jurcoane; M Nelles; A Müller; U Nöth; B Mädler; P Mürtz; R Deichmann; H H Schild
Journal:  Clin Neuroradiol       Date:  2015-07-30       Impact factor: 3.649

2.  Neural correlates of epigenesis.

Authors:  Turhan Canli; Maolin Qiu; Kazufumi Omura; Eliza Congdon; Brian W Haas; Zenab Amin; Martin J Herrmann; R Todd Constable; Klaus Peter Lesch
Journal:  Proc Natl Acad Sci U S A       Date:  2006-10-10       Impact factor: 11.205

Review 3.  Dynamic Contrast-Enhanced MR Imaging in Head and Neck Cancer: Techniques and Clinical Applications.

Authors:  S Gaddikeri; R S Gaddikeri; T Tailor; Y Anzai
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

4.  Relaxation by amplitude modulation: A rapid T1 measurement method.

Authors:  Xiaowei Zou; Truman R Brown
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

5.  Anesthetic effects on regional CBF, BOLD, and the coupling between task-induced changes in CBF and BOLD: an fMRI study in normal human subjects.

Authors:  Maolin Qiu; Ramachandran Ramani; Michael Swetye; Nallakkandi Rajeevan; R Todd Constable
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

6.  Arterial transit time effects in pulsed arterial spin labeling CBF mapping: insight from a PET and MR study in normal human subjects.

Authors:  Maolin Qiu; R Paul Maguire; Jagriti Arora; Beata Planeta-Wilson; David Weinzimmer; Jinghua Wang; Yuenan Wang; Hyeonjin Kim; Nallakkandi Rajeevan; Yiyun Huang; Richard E Carson; R Todd Constable
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

7.  Rapid T1 quantification based on 3D phase sensitive inversion recovery.

Authors:  Marcel J B Warntjes; Johan Kihlberg; Jan Engvall
Journal:  BMC Med Imaging       Date:  2010-08-17       Impact factor: 1.930

8.  pH-sensitive MRI demarcates graded tissue acidification during acute stroke - pH specificity enhancement with magnetization transfer and relaxation-normalized amide proton transfer (APT) MRI.

Authors:  Yingkun Guo; Iris Yuwen Zhou; Suk-Tak Chan; Yu Wang; Emiri T Mandeville; Takahiro Igarashi; Eng H Lo; Xunming Ji; Phillip Zhe Sun
Journal:  Neuroimage       Date:  2016-07-19       Impact factor: 6.556

9.  Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck.

Authors:  Jing Yuan; Steven Kwok Keung Chow; David Ka Wai Yeung; Anil T Ahuja; Ann D King
Journal:  Quant Imaging Med Surg       Date:  2012-12

10.  Spatial nonuniformity of the resting CBF and BOLD responses to sevoflurane: in vivo study of normal human subjects with magnetic resonance imaging.

Authors:  Maolin Qiu; Ramachandran Ramani; Michael Swetye; Robert Todd Constable
Journal:  Hum Brain Mapp       Date:  2008-12       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.