Literature DB >> 9806672

Autoregulation of human inner ear blood flow during middle ear surgery with propofol or isoflurane anesthesia during controlled hypotension.

M P Preckel1, C Ferber-Viart, G Leftheriotis, C Dubreuil, R Duclaux, J L Saumet, V Banssillon, J C Granry.   

Abstract

UNLABELLED: We used controlled hypotension to obtain a bloodless cavity during middle ear surgery under an optical microscope. No previous study has assessed the effect of controlled hypotension on inner ear blood flow (IEF) autoregulation in humans receiving propofol or isoflurane anesthesia. In the present study, the IEF autoregulation was determined using laser Doppler flowmetry in combination with transient evoked otoacoustic emissions (TEOAEs) during controlled hypotension with sodium nitroprusside in 20 patients randomly anesthetized with propofol or isoflurane. A coefficient of IEF autoregulation (Ga) was determined during controlled hypotension, with a Ga value ranging between 0 (no autoregulation) and 1 (perfect autoregulation). During controlled hypotension with propofol, IEF remained stable (1%+/-6%; P > 0.05) but decreased by 25%+/-8% with isoflurane (P < 0.05). The Ga was higher during propofol anesthesia (0.62+/-0.03) than during isoflurane anesthesia (0.22+/-0.03; P < 0.0001). Under propofol anesthesia, there were individual relationships between TEOAE amplitude and change in IEF in four patients. Such a correlation was not observed under isoflurane anesthesia. These results suggest that human IEF is autoregulated in response to decreased systemic pressure. Furthermore, isoflurane has a greater propensity to decrease cochlear autoregulation and function than propofol. IMPLICATIONS: The present study shows that inner ear blood flow is autoregulated under propofol, but not isoflurane, anesthesia during controlled hypotension in humans during middle ear surgery. Further studies are needed to explore the postoperative auditory functional consequences of the choice of the anesthetic drug used in middle ear surgery.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9806672     DOI: 10.1097/00000539-199811000-00004

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

1.  Effects of sevoflurane and desflurane on otoacoustic emissions in humans.

Authors:  Gurcan Gungor; Pervin Bozkurt-Sutas; Ozge Gedik; Ahmet Atas; Rovnat Babazade; Mehmet Yilmaz
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-06-11       Impact factor: 2.503

2.  The effects of hypotensive anaesthesia on otoacoustic emissions: a prospective, randomized, double-blind study with objective outcome measures.

Authors:  Ibrahim Aladag; Ziya Kaya; Levent Gurbuzler; Ahmet Eyibilen; Murat Songu; Duzgun Ates; Unal Erkorkmaz
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-01-07       Impact factor: 2.503

3.  Co-administration of cisplatin and furosemide causes rapid and massive loss of cochlear hair cells in mice.

Authors:  Yongqi Li; Dalian Ding; Haiyan Jiang; Yong Fu; Richard Salvi
Journal:  Neurotox Res       Date:  2011-04-01       Impact factor: 3.911

4.  Effects of ropivacaine on transient-evoked otoacoustic emissions: a rabbit model.

Authors:  Osman Kursat Arikan; Nuray Bayar Muluk; Bilgehan Budak; Alparslan Apan; Gurer Budak; Can Koc
Journal:  Eur Arch Otorhinolaryngol       Date:  2006-01-12       Impact factor: 2.503

5.  Gender differences in myogenic regulation along the vascular tree of the gerbil cochlea.

Authors:  Katrin Reimann; Gayathri Krishnamoorthy; Withrow Gil Wier; Philine Wangemann
Journal:  PLoS One       Date:  2011-09-29       Impact factor: 3.240

6.  Different effects of propofol and isoflurane on cochlear blood flow and hearing function in Guinea pigs.

Authors:  Ying Xiao; Jian Wen; Yanxia Bai; Na Duan; G X Jing
Journal:  PLoS One       Date:  2014-05-12       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.