Literature DB >> 9806364

Degradation of fibrinogen and cross-linked fibrin by human neutrophil elastase generates D-like fragments detected by ELISA but not latex D-dimer test.

E T Bach-Gansmo1, H C Godal, O H Skjønsberg.   

Abstract

Recently, we observed that D-dimers are degraded by human neutrophil elastase (HNE) into two D-like fragments, reacting with the monoclonal antibody in an ELISA D-dimer test but not reacting with the corresponding latex D-dimer test. To investigate this in more detail, we studied the degradation of cross-linked fibrin and fibrinogen by plasmin and HNE to see if this resulted in D-fragments or D-like fragments. Degradation of fibrinogen, both by plasmin and HNE, resulted in D- and D-like fragments, respectively, detected by the ELISA D-dimer test. Degradation of cross-linked fibrin by plasmin and HNE also resulted in D- and D-like fragments, which were detected by the ELISA method. Intact D-dimers detected by the latex D-dimer test were only observed after degradation of cross-linked fibrin with plasmin. We conclude that during lysis of cross-linked fibrin as well as fibrinogen by plasmin and HNE, D-fragments, and D-like fragments, detected by the ELISA D-dimer test, are formed. Only during degradation of cross-linked fibrin by plasmin, intact D-dimers, detected by latex D-dimer test, are formed. The ELISA D-dimer test may therefore be used to detect fibrin and fibrinogen degradation products generated by the combined action of plasmin and HNE in sepsis and other conditions with increased HNE activity, while the latex D-dimer test may be used to detect plasmin derived intact D-dimers.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9806364     DOI: 10.1016/s0049-3848(98)00121-2

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  4 in total

1.  Plasma proteomic profile associated with platelet dysfunction after trauma.

Authors:  Alexander St John; Yi Wang; Junmei Chen; Warren Osborn; Xu Wang; Esther Lim; Dominic Chung; Susan Stern; Nathan White; Xiaoyun Fu; José López
Journal:  J Thromb Haemost       Date:  2021-04-18       Impact factor: 5.824

2.  Quantitative determination of fibrinogen of patients with coronary heart diseases through piezoelectric agglutination sensor.

Authors:  Qinghai Chen; Xing Hua; Weiling Fu; Dongbo Liu; Ming Chen; Guoru Cai
Journal:  Sensors (Basel)       Date:  2010-03-16       Impact factor: 3.576

Review 3.  Coagulation in Lymphatic System.

Authors:  Wendi Zhang; Jiang Li; Jiangjiu Liang; Xiumei Qi; Jinghui Tian; Ju Liu
Journal:  Front Cardiovasc Med       Date:  2021-11-24

4.  Vascular occlusion by neutrophil extracellular traps in COVID-19.

Authors:  Moritz Leppkes; Jasmin Knopf; Elisabeth Naschberger; Aylin Lindemann; Jeeshan Singh; Irmgard Herrmann; Michael Stürzl; Léonie Staats; Aparna Mahajan; Christine Schauer; Anita N Kremer; Simon Völkl; Kerstin Amann; Katja Evert; Christina Falkeis; Andreas Wehrfritz; Ralf J Rieker; Arndt Hartmann; Andreas E Kremer; Markus F Neurath; Luis E Muñoz; Georg Schett; Martin Herrmann
Journal:  EBioMedicine       Date:  2020-07-31       Impact factor: 8.143

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.