Literature DB >> 9805118

Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters.

R K Fincher1, J S Strong, J L Jackson.   

Abstract

OBJECTIVE: To compare measurements of hemoglobin and potassium in blood samples obtained from peripheral venous catheters with measurements in samples obtained via venipuncture.
SUBJECTS: 53 adult volunteer patients admitted to a medical ward.
METHODS: For each patient, a 10-mL blood sample was obtained from a 20-gauge or larger peripheral venous catheter after a 3-mL volume of fluid was discarded. Immediately afterward, additional samples were obtained by venipuncture, and all samples were sent to the laboratory for measurement of hemoglobin and potassium levels. Separate venipuncture samples were obtained from both extremities in another 10 subjects to assess intratechnique variation. Results were analyzed by using limits-of-agreement analysis.
RESULTS: Blood samples were successfully obtained from a peripheral catheter in 32 (60%) of the 53 patients. The success rate was 78% with 18-gauge catheters and 42% with 20-gauge catheters (P = .021). The 95% agreement interval in the set of differences between values for samples obtained via catheter and samples obtained via venipuncture was +/- 0.37 mmol/L for potassium and +/- 7.6 g/L for hemoglobin. The 95% agreement interval for the venipuncture control group was +/- 0.21 mmol/L for potassium and +/- 7.3 g/L for hemoglobin. The preset acceptable interval for potassium measurements was +/- 0.3 mmol/L, and that for hemoglobin measurements was +/- 10 g/L.
CONCLUSIONS: Obtaining blood samples from peripheral catheters is an acceptable alternative to venipuncture for hemoglobin measurements but not for potassium measurements. Larger gauge catheters are better than small-gauge catheters for obtaining blood samples.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9805118

Source DB:  PubMed          Journal:  Am J Crit Care        ISSN: 1062-3264            Impact factor:   2.228


  7 in total

1.  Determining optimal waste volume from an intravenous catheter.

Authors:  Rachel B Baker; Suzanne S Summer; Michelle Lawrence; Amy Shova; Catherine A McGraw; Jane Khoury
Journal:  J Infus Nurs       Date:  2013 Mar-Apr

2.  Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters.

Authors:  Suzanne Adams; Bridget Toroni; Meenal Lele
Journal:  Nurs Res Pract       Date:  2018-05-22

3.  Baseline Soluble Anti-erythropoietin Antibody Level Is an Independent Associated Factor for Follow-Up Erythropoietin Demand in Maintenance Dialysis Patients With End-Stage Renal Disease: A Prospective Cohort Study.

Authors:  Ying Zhang; Shi-Zhu Bian; Kun Yang; Yiqing Wang; Sha Tang; Weili Wang; Daihong Wang; Ling Nie; Jinghong Zhao
Journal:  Front Med (Lausanne)       Date:  2020-04-07

4.  Intra-patient potassium variability after hypothermic cardiac arrest: a multicentre, prospective study.

Authors:  M Pasquier; M Blancher; S Buse; B Boussat; G Debaty; M Kirsch; M de Riedmatten; P Schoettker; T Annecke; P Bouzat
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2019-12-16       Impact factor: 2.953

5.  Comparison of biochemical and hematologic values obtained via jugular venipuncture and peripheral intravenous catheters in dogs.

Authors:  Aria L Guarino; Andrew J Specht; Sarah S K Beatty; Allison L O'Kell
Journal:  J Vet Intern Med       Date:  2022-08-27       Impact factor: 3.175

6.  Relationship of Common Vascular Anatomy to Cannulated Catheters.

Authors:  Paul Gagne; Karun Sharma
Journal:  Int J Vasc Med       Date:  2017-12-19

7.  Blood sampled from existing peripheral IV cannulae yields results equivalent to venepuncture: a systematic review.

Authors:  Finnian D Lesser; David A Lanham; Daniel Davis
Journal:  JRSM Open       Date:  2020-05-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.