Literature DB >> 9802660

Patellofemoral complications in symmetrical total knee arthroplasty.

S F Harwin1.   

Abstract

A review of 356 Kinemax (Howmedica, Inc, Rutherford, NJ) cemented posterior cruciate ligament-retaining condylar total knee arthroplasties employing a symmetrical femoral component articulating with a medially offset symmetrical dome patella component was carried out to examine the results and determine the incidence and nature of the patellofemoral complications. Follow-up was from 3 to 8 years, with a mean of 5.1 years. A review of patellofemoral complications in previously reported homogeneous series of symmetrical and asymmetrical implants is presented. Mean postoperative Knee Society scores improved to 91, function scores to 86, and Hospital of Special Surgery scores to 90 yielding 95% good and excellent results. Mean postoperative range of motion was -1.5 degrees extension to 113 degrees flexion. There were five patellofemoral complications (1.4%), including two symptomatic subluxations, two distal pole avulsion fractures, and one lateral facet fracture. There were two reoperations necessary for patellofemoral problems (0.56%), one to correct subluxation and one for excision of the fractured lateral facet. These rates are lower than those previously reported for asymmetrical implants as well as current and phased-out symmetrical designs of total knee arthroplasty in the intermediate term. This review suggests that cemented total knee arthroplasty with symmetrical patellofemoral resurfacing with an offset patella dome and posterior cruciate ligament retention yields low patellofemoral complications and reoperations. The symmetrical femoral component appears to be a satisfactory compromise of "normal" femoral anatomy, which decreases inventory and cost without adversely affecting patellofemoral function and complications.

Entities:  

Mesh:

Year:  1998        PMID: 9802660     DOI: 10.1016/s0883-5403(98)90026-2

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

1.  The femoral sulcus in total knee arthroplasty.

Authors:  Krishna Lingaraj; John Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-31       Impact factor: 4.342

2.  Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

Authors:  Omer Faruk Erkocak; Fatih Kucukdurmaz; Safak Sayar; Mehmet Emin Erdil; Hasan Huseyin Ceylan; Ibrahim Tuncay
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-04-24       Impact factor: 4.342

3.  Results of total knee replacement with/without resurfacing of the patella.

Authors:  Abdul Khan; Nikhil Pradhan
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

4.  Radiographic features predictive of patellar maltracking during total knee arthroplasty.

Authors:  Shi-Lu Chia; Azhar M Merican; Bernard Devadasan; Robin K Strachan; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-06-16       Impact factor: 4.342

5.  An alternative patellar resurfacing technique in knee replacement: patellofemoral fascial interposition arthroplasty.

Authors:  Volkan Oztuna; Vasfi Karatosun; Bayram Unver; Irfan Ayan; Fehmi Kuyurtar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-07-10       Impact factor: 4.342

6.  Correlation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants.

Authors:  Elham Karimi; Reza Zandi; Mohsen Norouzian; Ali Birjandinejad
Journal:  Arch Bone Jt Surg       Date:  2019-07

7.  Use of porous monoblock patella component should avoid for patient with patella baja.

Authors:  Takao Kaneko; Norihiko Kono; Yuta Mochizuki; Hiroyasu Ikegami; Yoshiro Musha
Journal:  J Orthop       Date:  2018-03-23

8.  Patellar tracking during total knee arthroplasty: an in vitro feasibility study.

Authors:  C Belvedere; F Catani; A Ensini; J L Moctezuma de la Barrera; A Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-04-13       Impact factor: 4.114

9.  Similar TKA designs with differences in clinical outcome: a randomized, controlled trial of 77 knees with a mean follow-up of 6 years.

Authors:  Huub J Meijerink; Nico Verdonschot; Corné J M van Loon; Gerjon Hannink; Maarten C de Waalmalefijt
Journal:  Acta Orthop       Date:  2011-11-09       Impact factor: 3.717

10.  Dynamic in vitro measurement of patellar movement after total knee arthroplasty: an in vitro study.

Authors:  Sven Ostermeier; Olaf Buhrmester; Christof Hurschler; Christina Stukenborg-Colsman
Journal:  BMC Musculoskelet Disord       Date:  2005-06-15       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.