Literature DB >> 9801286

Line-associated bloodstream infections in pediatric intensive-care-unit patients associated with a needleless device and intermittent intravenous therapy.

L C McDonald1, S N Banerjee, W R Jarvis.   

Abstract

OBJECTIVES: To determine risk factors for an increase in line-associated bloodstream infections (BSIs) in three pediatric intensive-care units at one hospital that recently had changed brands of needleless access device.
DESIGN: Retrospective case-control studies; review of the units' infection control policies and procedures for accessing and replacing components of needleless access devices.
SETTING: A community tertiary-care hospital's three pediatric intensive-care units. PATIENTS: Children in one of the three intensive-care units with a central venous catheter in place during January 1, 1995, through May 15, 1996, who developed laboratory-confirmed primary BSI. Children who had central venous catheters in place for >48 hours and who did not develop BSI were chosen randomly as controls.
RESULTS: Eight patients met the case definition; they had 11 episodes of BSI. Multivariate analysis identified duration of catheterization and exposure to the IVAC first-generation needleless device as independent risk factors for BSI. Compared with patients from another pediatric intensive-care unit in which the IVAC device also was used but in which an increased BSI rate did not occur, patients from the unit with an increased BSI rate were more likely to receive intermittent (vs continuous) intravenous therapy through one or more lumens. In both units, the IVAC device valve component was replaced every 6 days, and the endcap used to cover the valve (when connected to an unused lumen) was replaced every 24 hours or after each access. The BSI rate returned to baseline after institution of a policy to replace the entire IVAC device, valve, and endcap every 24 hours.
CONCLUSIONS: An increased risk of BSI was associated with use of the IVAC first-generation needleless device when replaced every 6 days. This increased risk may have been more pronounced in one pediatric intensive-care unit, because patients were more likely to receive intermittent intravenous therapy. Intermittent intravenous therapy or central venous catheter flushing practices may be important determinants of BSI risk.

Entities:  

Mesh:

Year:  1998        PMID: 9801286     DOI: 10.1086/647722

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  4 in total

1.  Summary of recommendations: Guidelines for the Prevention of Intravascular Catheter-related Infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-05       Impact factor: 9.079

2.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-04-01       Impact factor: 9.079

3.  Reduction of central line-associated bloodstream infection rates in a neonatal intensive care unit after implementation of a multidisciplinary evidence-based quality improvement collaborative: A four-year surveillance.

Authors:  Joseph Y Ting; Vicki Sk Goh; Horacio Osiovich
Journal:  Can J Infect Dis Med Microbiol       Date:  2013       Impact factor: 2.471

4.  Implementation of continuous capnography is associated with a decreased utilization of blood gases.

Authors:  Courtney M Rowan; Richard H Speicher; Terri Hedlund; Sheikh S Ahmed; Nancy L Swigonski
Journal:  J Clin Med Res       Date:  2014-11-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.