Literature DB >> 9797148

Continuous assessment of perfusion by tagging including volume and water extraction (CAPTIVE): a steady-state contrast agent technique for measuring blood flow, relative blood volume fraction, and the water extraction fraction.

G Zaharchuk1, A A Bogdanov, J J Marota, M Shimizu-Sasamata, R M Weisskoff, K K Kwong, B G Jenkins, R Weissleder, B R Rosen.   

Abstract

A new technique, CAPTIVE, that is a synthesis of arterial spin labeling (ASL) blood flow and steady-state susceptibility contrast relative blood volume imaging is described. Using a single injection of a novel, long half-life intravascular magnetopharmaceutical with a high tissue:blood susceptibility difference (deltachi) to deltaR1 ratio, changes in tissue transverse relaxivity (deltaR2 or deltaR2*) that arise from changes in blood volume were measured, while preserving the ability to measure blood flow using traditional T1-based ASL techniques. This modification permits the continuous measurement of both blood flow and blood volume. Also, because the contrast agent can be used to remove the signal from intravascular spins, it is possible to measure the first-pass water extraction fraction. Contrast-to-noise is easily traded off with repetition rate, allowing the use of non-EPI scanners and more flexible imaging paradigms. The basic theory of these measurements, several experimental scenarios, and validating results are presented. Specifically, the PaCO2-reactivity of microvascular and total relative cerebral blood volume (rCBV), cerebral blood flow (CBF), and the water extraction-flow product (EF) in rats with the new contrast agent MPEG-PL-DyDTPA is measured, and the values are concordant with those of previous literature. As an example of one possible application, continuous flow and volume measurements during transient focal ischemia are presented. It is believed that CAPTIVE imaging will yield a more complete picture of the hemodynamic state of an organ, and has further application for understanding the origins of the BOLD effect.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9797148     DOI: 10.1002/mrm.1910400504

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

Review 1.  Molecular brain imaging in the multimodality era.

Authors:  Julie C Price
Journal:  J Cereb Blood Flow Metab       Date:  2012-03-21       Impact factor: 6.200

2.  Measuring biexponential transverse relaxation of the ASL signal at 9.4 T to estimate arterial oxygen saturation and the time of exchange of labeled blood water into cortical brain tissue.

Authors:  Jack A Wells; Bernard Siow; Mark F Lythgoe; David L Thomas
Journal:  J Cereb Blood Flow Metab       Date:  2012-11-21       Impact factor: 6.200

3.  Dynamic functional cerebral blood volume responses to normobaric hyperoxia in acute ischemic stroke.

Authors:  Ona Wu; Jie Lu; Joseph B Mandeville; Yoshihiro Murata; Yasu Egi; Guangping Dai; John J Marota; Izzuddin Diwan; Rick M Dijkhuizen; Kenneth K Kwong; Eng H Lo; Aneesh B Singhal
Journal:  J Cereb Blood Flow Metab       Date:  2012-06-27       Impact factor: 6.200

4.  A two-stage approach for measuring vascular water exchange and arterial transit time by diffusion-weighted perfusion MRI.

Authors:  Keith S St Lawrence; Daron Owen; Danny J J Wang
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

5.  Functional response of tumor vasculature to PaCO2: determination of total and microvascular blood volume by MRI.

Authors:  Scott D Packard; Joseph B Mandeville; Tomotsugu Ichikawa; Keiro Ikeda; Kinya Terada; Stephanie Niloff; E Antonio Chiocca; Bruce R Rosen; John J A Marota
Journal:  Neoplasia       Date:  2003 Jul-Aug       Impact factor: 5.715

6.  Protected Graft Copolymer (PGC) in Imaging and Therapy: A Platform for the Delivery of Covalently and Non-Covalently Bound Drugs.

Authors:  Alexei A Bogdanov; Mary Mazzanti; Gerardo Castillo; Elijah Bolotin
Journal:  Theranostics       Date:  2012-06-04       Impact factor: 11.556

7.  Noncontrast assessment of blood-brain barrier permeability to water: Shorter acquisition, test-retest reproducibility, and comparison with contrast-based method.

Authors:  Zixuan Lin; Dengrong Jiang; Dapeng Liu; Yang Li; Jinsoo Uh; Xirui Hou; Jay J Pillai; Qin Qin; Yulin Ge; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2021-02-08       Impact factor: 3.737

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.