Comparison of arachnoiditis produced by meglumine iocarmate and metrizamide myelography in an animal model.

V M Haughton, K C Ho, S J Larson, G F Unger, F Correa-Paz.   

Abstract

Myelography in monkeys was performed with either meglumine iocarmate or metrizamide. The severity of resultant arachnoiditis in each animal 12 weeks later was evaluated by repeat myelography and by histologic study of the arachnoid. Three of the four animals examined with meglumine iocarmate had severe arachnoiditis; none of the four animals examined with metrizamide had as severe changes. The difference between the two groups was statistically significant (P less than .05).

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 97964     DOI: 10.2214/ajr.131.1.129

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  Computed tomography and spinal dysraphism: clinical and phantom studies.

Authors:  J H Scatliff; W D Bidgood; K Killebrew; E V Staab
Journal:  Neuroradiology       Date:  1979-02-26       Impact factor: 2.804

2.  Subacute reactions to intrathecal amipaque (metrizamide), conray and dimer X: a structural and ultrastructural study.

Authors:  B C Lee; D G Gomez; D G Potts; A M Pavese
Journal:  Neuroradiology       Date:  1981-01       Impact factor: 2.804