Literature DB >> 9795843

Clear lens extraction and implantation of negative-power posterior chamber intraocular lenses to correct extreme myopia.

I Jiménez-Alfaro1, S Miguélez, J L Bueno, P Puy.   

Abstract

PURPOSE: To evaluate the effectiveness, predictability, and safety of clear lens extraction to correct extreme myopia.
SETTING: Clinica de Nuestra Señora de la Concepción, Fundación Jiménez Díaz, Madrid, Spain.
METHODS: This retrospective study comprised 26 eyes of 17 highly myopic patients who had clear lens extraction and implantation of a negative-power posterior chamber intraocular lens (IOL). The IOL power was calculated using the SRK/T formula. Analyzed were visual and refractive results and intraoperative and postoperative complications. Follow-up was at least 12 months in all cases.
RESULTS: Uncorrected visual acuity improved in all cases, with 80.77% of eyes achieving 20/100 or better and 42.30%, 20/40 or better. Best spectacle-corrected visual acuity (BSCVA) improved in 23 eyes (88.46%). The percentage of eyes achieving a BSCVA of 20/100 or better increased from 73.07% preoperatively to 92.30% postoperatively and the percentage achieving 20/40 or better, from 23.07 to 73.07%. Of the 26 eyes, 76.91% were within 1.00 diopter (D) of refractive error and 96.16% were within 2.00 D. No intraoperative complications occurred. Although postoperatively 3 eyes (11.53%) developed choroidal detachment and 5 (19.23%) had an intraocular pressure greater than 25 mm Hg, all had a favorable outcome. Four eyes (15.38%) developed posterior capsule opacification and had a neodymium:YAG laser posterior capsulotomy 6 months postoperatively. No retinal detachments were observed.
CONCLUSION: Clear lens extraction with negative-power IOL implantation using the SRK/T formula had good effectiveness, acceptable predictability, and a low morbidity in eyes with extreme myopia over a short follow-up. A longer follow-up with more cases is needed to assess the safety of the procedure.

Entities:  

Mesh:

Year:  1998        PMID: 9795843     DOI: 10.1016/s0886-3350(98)80220-4

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

1.  The changing face of refractive surgery.

Authors:  S Shah; H S Dua
Journal:  BMJ       Date:  2000-02-12

2.  Comparison of formulas and methods for high myopia patients requiring intraocular lens powers less than six diopters.

Authors:  Harry S Geggel
Journal:  Int Ophthalmol       Date:  2017-06-20       Impact factor: 2.031

Review 3.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 4.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

Review 5.  [Complications after refractive lens exchange].

Authors:  D Kook; A Kampik; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

6.  Binocular visual function of myopic pseudophakic monovision.

Authors:  Ken Hayashi; Motoaki Yoshida; Hiroshi Sasaki; Akira Hirata
Journal:  Jpn J Ophthalmol       Date:  2018-02-20       Impact factor: 2.447

7.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

Review 8.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

Review 9.  Refractive lens exchange in modern practice: when and when not to do it?

Authors:  Jorge L Alió; Andrzej Grzybowski; Dorota Romaniuk
Journal:  Eye Vis (Lond)       Date:  2014-12-10

10.  Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study.

Authors:  Chong Chen; Xian Xu; Yuyu Miao; Gaoxin Zheng; Yong Sun; Xun Xu
Journal:  J Ophthalmol       Date:  2015-12-17       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.