Literature DB >> 9794684

Newborn acid-base status and umbilical cord morphology.

R K Atalla1, K Abrams, S C Bell, D J Taylor.   

Abstract

OBJECTIVE: To assess the relation between umbilical cord morphology and intrapartum fetal status and umbilical cord blood gases at birth.
METHODS: In a prospective study of 134 consecutive newborns and their umbilical cords, relations were investigated between umbilical cord morphologic characteristics (umbilical cord length, number of vascular coils, coiling index, and vessel length index) and intrapartum fetal heart rate (FHR) decelerations, color of amniotic fluid, operative delivery for suspected fetal acidosis, umbilical vessel blood gases, and acid-base status.
RESULTS: Statistically significant linear correlations were found between umbilical venous pH and the umbilical cord length (r = 0.30; 95% confidence interval [CI] 0.13, 0.46; P < .001), number of vascular coils (r = 0.27; 95% CI 0.10, 0.43; P = .001), coiling index (r = 0.15; 95% CI 0, 0.33; P = .05), and vessel length index (r = 0.30; 95% CI 0.13, 0.46; P < .001). Statistically significant negative linear correlations were found between the umbilical venous partial pressure of carbon dioxide (PCO2) and cord length (r = -0.34, 95% CI -0.49, -0.17; P < .001), number of vascular coils (r = -0.30, 95% CI -0.46, -0.13; P < .001), coiling index (r = -0.17, 95% CI -0.34, 0; P = .03), and vessel length index (r = -0.34, 95% CI -0.49, -0.17; P < .001). The umbilical artery pH was related to vessel length index and to the number of umbilical vascular coils (r = 0.17, 95% CI 0.03, 0.36; P = .04 and r = 0.17, 95% CI 0.02, 0.35; P = .047, respectively). No relation was found between umbilical cord indices and intrapartum FHR decelerations, meconium staining of the amniotic fluid, or mode of delivery. Placental weight also correlated with umbilical cord length and vessel length index (95% CI 0.15, 0.46; P < .001 and 95% CI 0.05, 0.38; P = .01, respectively), but not with the number of umbilical cord coils or the coiling index.
CONCLUSION: Umbilical venous pH and PCO2 and umbilical artery pH are related to umbilical cord morphology. Associated variations in placental morphology or placental blood flow affecting maternal-fetal gas exchange may explain these findings.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9794684     DOI: 10.1016/s0029-7844(98)00316-0

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  4 in total

Review 1.  Use of umbilical cord blood gas analysis in the assessment of the newborn.

Authors:  L Armstrong; B J Stenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-11       Impact factor: 5.747

2.  Study of length of umbilical cord and fetal outcome: a study of 1,000 deliveries.

Authors:  Nilesh Unmesh Balkawade; Mangala Ashok Shinde
Journal:  J Obstet Gynaecol India       Date:  2012-10-03

3.  The effects of a history of seizures during pregnancy on umbilical arterial blood gas values in pregnant women with epilepsy.

Authors:  Ozhan Ozdemir; Mustafa Erkan Sarı; Funda Arpacı Ertuğrul; Aslıhan Kurt; Vefa Selimova; Cemal Reşat Atalay
Journal:  J Turk Ger Gynecol Assoc       Date:  2014-08-08

4.  Gestational diabetes mellitus: the correlation between umbilical coiling index, and intrapartum as well as neonatal outcomes.

Authors:  Laily Najafi; Azadeh Abedini; Maryam Kadivar; Alireza Khajavi; Arash Bordbar; Amir Hussein Noohi; Banafsheh Mashak; Maryam Hashemnejad; Mohammad E Khamseh; Mojtaba Malek
Journal:  J Diabetes Metab Disord       Date:  2019-04-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.