Literature DB >> 9793478

Comparison of methods for monitoring solid particulate surface contamination in the workplace.

J P Wheeler1, J D Stancliffe.   

Abstract

This paper reports an assessment of various methods for sampling particulate surface contamination for use in the field. The results from the study will be used to develop guidance for monitoring particulate surface contamination in the workplace. Three types of adhesive tape, two manual and two 'semi-automatic' wipe methods, and one Smair method were assessed. A field assessment of selected methods was carried out in two stages. In stage one, the manual wipes, semi-automatic wipes and adhesive tape (Scotch Tape) were compared. In stage two, the adhesive tape (Scotch Tape), black forensic tape, clear forensic tape and Smair were compared. Visits were made to ten metal processing facilities and particulate contamination was sampled from six locations at each site. Sampling locations were chosen for their potential as points of worker dermal contact and also to represent a range of surface characteristics. The metal content of the samples were analysed using Atomic Absorption Spectrophotometry (AAS) and X-ray Fluorescence Spectrometry (XRF). It was found that the Smair method proved to be inefficient in removing surface contamination, particularly where the surface was damp or greasy. Tape methods were found to be the most satisfactory and have considerably greater efficiency than wipe sampling. The black forensic tape is the preferred sampling medium as it is highly efficient, reproducible and easy to use.

Entities:  

Mesh:

Year:  1998        PMID: 9793478     DOI: 10.1016/s0003-4878(98)00057-x

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  4 in total

1.  Conceptual model for assessment of dermal exposure.

Authors:  T Schneider; R Vermeulen; D H Brouwer; J W Cherrie; H Kromhout; C L Fogh
Journal:  Occup Environ Med       Date:  1999-11       Impact factor: 4.402

2.  Immediate screening of lead exposure in the workplace using portable X-ray fluorescence.

Authors:  Jean-Philippe Gorce; Martin Roff
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

3.  Determination of Metal Impurities in Carbon Nanotubes Sampled Using Surface Wipes.

Authors:  Mary-Luyza Avramescu; Pat E Rasmussen; Marc Chénier
Journal:  J Anal Methods Chem       Date:  2016-11-16       Impact factor: 2.193

4.  The use of bio-monitoring to assess exposure in the electroplating industry.

Authors:  Helen Beattie; Chris Keen; Matthew Coldwell; Emma Tan; Jackie Morton; John McAlinden; Paul Smith
Journal:  J Expo Sci Environ Epidemiol       Date:  2015-12-02       Impact factor: 5.563