Literature DB >> 9792267

Stent implantation of the arterial duct in newborns with duct-dependent circulation.

M Schneider1, P Zartner, A Sidiropoulos, W Konertz, G Hausdorf.   

Abstract

AIMS: Little is known about the medium term results after stenting of the arterial duct in neonates and infants with duct-dependent cyanotic congenital heart disease. We report the results of stent implantation of the arterial duct in 21 neonates and infants. The defects for which the arterial duct was stented included pulmonary atresia with intact ventricular septum, critical pulmonary stenosis, and more complex defects with associated reduced pulmonary blood flow. METHODS AND
RESULTS: Palmaz stents were used and successfully implanted in all the 21 patients. There were no major complications during the stent implantation procedure although two hospital deaths occurred 2 and 14 days after stent implantation. Cardiac catheterization was repeated electively 3 to 6 months after stent implantation. Stent stenosis due to intimal proliferation was noted in 11/13 patients who underwent recatheterization. Stenosis of the inner stent lumen ranged from 25% to 100%, mean 74%. Re-dilatation of the stent was required in five patients who were awaiting corrective surgery. In babies with pulmonary atresia or critical pulmonary stenosis, who also underwent additional balloon dilatation of the pulmonary valve, spontaneous closure of the stented arterial duct was well tolerated and when it occurred, the right ventricular size had increased and the circulation was no longer duct-dependent. In patients who required subsequent surgical corrective treatment, stenting of the duct allowed the definite corrective operation to be performed as the first surgical procedure. During the follow-up period, ranging between 2 months and 2 years, mean 8.7 months increased growth of the pulmonary arteries was seen in all the patients. No distortion of the branch pulmonary arteries was seen.
CONCLUSION: In patients with cyanotic congenital heart disease stenting of the arterial duct is an effective alternative to surgical aorto-pulmonary shunts.

Entities:  

Mesh:

Year:  1998        PMID: 9792267     DOI: 10.1053/euhj.1998.0977

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  21 in total

1.  Transcatheter palliation of tetralogy of Fallot with pulmonary artery discontinuity.

Authors:  Giuseppe Santoro; Maurizio Cappelli Bigazzi; Maria Teresa Palladino; Maria Giovanna Russo; Marianna Carrozza; Raffaele Calabrò
Journal:  Tex Heart Inst J       Date:  2005

Review 2.  Novel drug targets for ductus arteriosus manipulation: Looking beyond prostaglandins.

Authors:  Elaine L Shelton; Gautam K Singh; Colin G Nichols
Journal:  Semin Perinatol       Date:  2018-05-10       Impact factor: 3.300

3.  Stenting of ductus arteriosus in a neonate with truncus arteriosus and interrupted aortic arch associated with a right aortic arch.

Authors:  Miho Sakata; Yasunobu Hayabuchi; Miki Inoue; Shoji Kagami
Journal:  Pediatr Cardiol       Date:  2009-08-25       Impact factor: 1.655

4.  Ductal stent implantation in tetralogy of fallot with aortic arch abnormality.

Authors:  Hasan Tahsin Tola; Yakup Ergul; Murat Saygi; Isa Ozyilmaz; Alper Guzeltas; Ender Odemis
Journal:  Tex Heart Inst J       Date:  2015-06-01

5.  Short-term result of ductus arteriosus stent implantation compared with surgically created shunts.

Authors:  Hamid Amoozgar; Sirous Cheriki; Mohammad Borzoee; Gholamhossein Ajami; Manouchehr Soltani; Maryam Ahmadipour; Farah Peiravian; Amirali Amirghofran
Journal:  Pediatr Cardiol       Date:  2012-03-25       Impact factor: 1.655

6.  Stent implantation of patent ductus arteriosus in a newborn baby.

Authors:  Prabhat Kumar; R Datta; R Nair; G Sridhar
Journal:  Med J Armed Forces India       Date:  2011-07-21

7.  Neonatal patent ductus arteriosus recanalization and stenting in critical Ebstein's anomaly.

Authors:  G Santoro; M T Palladino; M G Russo; R Calabrò
Journal:  Pediatr Cardiol       Date:  2007-09-15       Impact factor: 1.655

8.  Axillary artery access for cardiac interventions in newborns.

Authors:  Dietmar Schranz; Ina Michel-Behnke
Journal:  Ann Pediatr Cardiol       Date:  2008-07

9.  Stenting the ductus arteriosus: Case selection, technique and possible complications.

Authors:  Mazeni Alwi
Journal:  Ann Pediatr Cardiol       Date:  2008-01

10.  The role of stents in the treatment of congenital heart disease: Current status and future perspectives.

Authors:  Bjoern Peters; Peter Ewert; Felix Berger
Journal:  Ann Pediatr Cardiol       Date:  2009-01
View more