Ultrasound biomicroscopic imaging of posterior chamber phakic intraocular lens.

F Trindade1, F Pereira, S Cronemberger.   

Abstract

BACKGROUND: Phakic intraocular lens (IOL) implantation represents a major technique for the correction of high myopia. The STAAR collamer posterior chamber phakic IOL--trade named Implantable Contact Lens--is an emerging technology in refractive surgery. We studied the relative position of the posterior chamber phakic IOL using ultrasound biomicroscopy.
METHODS: The posterior chamber phakic intraocular lens was inserted in 9 eyes of 8 patients with high myopia. Ultrasound biomicroscopy was performed before and after implantation of the phakic IOL to assess its relative position in the anterior segment of the eye. The parameters measured and compared were anterior chamber depth, angle opening distance 500 microns from the scleral spur, iris-crystalline lens contact distance, iris-IOL contact distance, and IOL-crystalline lens distance.
RESULTS: Ultrasound biomicroscopy showed contact between the iris and the IOL in all eyes and between the IOL and the crystalline lens in 8 eyes. Reduction in the anterior chamber depth and localized narrowing of the angle opening were observed in all eyes.
CONCLUSION: IOL-iris touch, IOL-crystalline lens touch, and anterior chamber shallowing raise concerns of pigmentary dispersion, cataractogenesis, and narrow angle glaucoma following posterior chamber phakic intraocular lens implantation. Clinical data are needed to determine if these problems occur.

Entities:  

Mesh:

Year:  1998        PMID: 9791815     DOI: 10.3928/1081-597X-19980901-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

Review 1.  Anterior segment imaging: ultrasound biomicroscopy.

Authors:  Hiroshi Ishikawa; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

2.  Ultrasonography of the Anterior Segment.

Authors:  Martin Heur; Bennie H Jeng
Journal:  Ultrasound Clin       Date:  2008-04-01

Review 3.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 4.  Potential complications of phakic IOLs.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

Review 5.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

6.  Posterior chamber phakic intraocular lens implantation for high myopia.

Authors:  Yan Ju; Xiao-Wei Gao; Bing Ren
Journal:  Int J Ophthalmol       Date:  2013-12-18       Impact factor: 1.779

7.  Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology.

Authors:  Zhikun Yang; Lihui Meng; Xinyu Zhao; Youxin Chen; Yan Luo
Journal:  Front Med (Lausanne)       Date:  2022-06-09

8.  Biomechanical properties of human corneas following low- and high-intensity collagen cross-linking determined with scanning acoustic microscopy.

Authors:  Ithar M Beshtawi; Riaz Akhtar; M Chantal Hillarby; Clare O'Donnell; Xuegen Zhao; Arun Brahma; Fiona Carley; Brian Derby; Hema Radhakrishnan
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-08-07       Impact factor: 4.799

  8 in total