Literature DB >> 9788408

High-precision conformal radiotherapy (HPCRT) of prostate cancer--a new technique for exact positioning of the prostate at the time of treatment.

P Bergström1, P O Löfroth, A Widmark.   

Abstract

PURPOSE: Biopsies taken 2 years after radiotherapy of localized prostate cancer indicate residual tumor cells in 20-60% of cases, and the prognosis for these patients is unfavorable. More precise methods of localization of the prostate are desirable to increase the dose to the prostate tumor and minimize the volume of adjacent sensitive tissues that are currently included in the planning target volume. We have sought a method to more accurately locate the prostate at the time of treatment, allowing a reduction of the volume of rectum and bladder included in the high dose region during dose escalation. METHODS AND
RESULTS: We have developed a new technique using a special urethral catheter (patent pending), containing markers that can be visualized by the radiotherapy machine for accurate positioning of the prostate. The catheter is used throughout the treatment planning procedure and the isocenter is placed on one of the markers. On the treatment couch the markers are visualized on port-films and with portal imaging immediately before dose delivery. A beam-center-marker on the accelerator makes it possible to adjust the isocenter position to within 1 mm, giving very high precision, independent of external fixation. The technique involves a simple patient setup. The method has been tested in five patients with conventional dose level (70 Gy) and in 24 patients in the first Scandinavian dose escalation study with external beam radiotherapy. No increase in acute side-effects was observed.
CONCLUSION: With the new high precision conformal radiotherapy (HPCRT) technique we have developed a technique that allows us to increase the dose to the prostate without excessive side effects. The method reduces the uncertainties in prostate localization, is easy to handle, and feasible in routine treatment.

Entities:  

Mesh:

Year:  1998        PMID: 9788408     DOI: 10.1016/s0360-3016(98)00229-6

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

1.  A novel approach for establishing benchmark CBCT/CT deformable image registrations in prostate cancer radiotherapy.

Authors:  Jinkoo Kim; Sanath Kumar; Chang Liu; Hualiang Zhong; Deepak Pradhan; Mira Shah; Richard Cattaneo; Raphael Yechieli; Jared R Robbins; Mohamed A Elshaikh; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2013-10-31       Impact factor: 3.609

2.  Development of CBCT-based prostate setup correction strategies and impact of rectal distension.

Authors:  Christine Boydev; Abdelmalik Taleb-Ahmed; Foued Derraz; Laurent Peyrodie; Jean-Philippe Thiran; David Pasquier
Journal:  Radiat Oncol       Date:  2015-04-10       Impact factor: 3.481

3.  Reconstruction of the treatment area by use of sinogram in helical tomotherapy.

Authors:  Akihiro Haga; Keiichi Nakagawa; Calvin Maurer; Ken Ruchala; Edward Chao; Dylan Casey; Satoshi Kida; Dousatsu Sakata; Masahiro Nakano; Taiki Magome; Yoshitaka Masutani
Journal:  Radiat Oncol       Date:  2014-11-28       Impact factor: 3.481

4.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

5.  Theoretical foundation for real-time prostate localization using an inductively coupled transmitter and a superconducting quantum interference device (SQUID) magnetometer system.

Authors:  John E McGary
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

6.  Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance.

Authors:  Joen Sveistrup; Per Munck af Rosenschöld; Joseph O Deasy; Jung Hun Oh; Tobias Pommer; Peter Meidahl Petersen; Svend Aage Engelholm
Journal:  Radiat Oncol       Date:  2014-02-04       Impact factor: 3.481

7.  Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.

Authors:  Felix Böckelmann; Florian Putz; Karoline Kallis; Sebastian Lettmaier; Rainer Fietkau; Christoph Bert
Journal:  Strahlenther Onkol       Date:  2020-03-10       Impact factor: 3.621