Literature DB >> 9787224

The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses.

F M Mutlu1, A H Bilge, H I Altinsoy, E Yumusak.   

Abstract

The purpose of this study is to determine the effects of different anterior capsulotomy techniques and intraocular lens (IOL) types on IOL tilt and decentration. For this purpose the device using Purkinje reflections and photographic documentation were evaluated. A total of 107 cataractous eyes undergoing IOL implant surgery were divided into four groups based on the type of IOL and capsulotomy: group 1, single-piece polymethylmethacrylate (PMMA) IOL with a haptic distance of 13.50 mm; group 2, single-piece PMMA IOL with 12. 0 mm overall length; group 3, three-piece foldable acrylic IOL with 13.00 mm PMMA haptic distance; group 4, the same IOL as group 1. While continuous circular capsulorhexis was the type of capsulotomy in the first three groups, envelope capsulotomy was used in group 4. Mean tilt and decentration were significantly less when capsulorhexis technique was used in comparison with envelope capsulotomy. Mean tilt of group 1 (2.83+/-0.89 degrees) and mean decentration of group 2 (0.28+/-0.14 mm) were higher within the first three groups. The differences regarding both the IOL decentration and tilt between the first three groups were statistically significant. This study shows that if the IOLs were placed properly in the capsular bag after continuous circular capsulorhexis, foldable acrylic IOLs with PMMA haptics are superior in terms of tilt and decentration.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9787224     DOI: 10.1159/000027368

Source DB:  PubMed          Journal:  Ophthalmologica        ISSN: 0030-3755            Impact factor:   3.250


  3 in total

1.  [Functional results with two multifocal intraocular lenses (MIOL). Array SA40 versus Acri.Twin].

Authors:  U Mester; P Dillinger; N Anterist; H Kaymak
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

2.  Comparison of postoperative axial stability of intraocular lens and capsulotomy parameters between precision pulse capsulotomy and continuous curvilinear capsulotomy: A prospective cohort study.

Authors:  Seung Pil Bang; Jong Hwa Jun
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

3.  IOL tilt and decentration estimation from 3 dimensional reconstruction of OCT image.

Authors:  Xiaogang Wang; Jing Dong; Xiaoliang Wang; Qiang Wu
Journal:  PLoS One       Date:  2013-03-15       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.