Literature DB >> 9786591

A quadricuspid aortic valve diagnosed by transesophageal echocardiography: report of a case.

T Watanabe1, Y Hosoda, S Sasaguri, Y Aikawa.   

Abstract

A quadricuspid aortic valve is a very rare anomaly which may cause aortic regurgitation in adulthood. We describe herein the case of a 54-year-old man with aortic regurgitation in whom a quadricuspid aortic valve was diagnosed, not through transthoracic investigation, but by transesophageal echocardiography (TEE). TEE also indicated that the right coronary ostium was located in a lower position. Subsequent aortic valve replacement was successfully performed, at which time the diagnosis was confirmed. Thus, TEE played an important role in identifying the anatomy of the aortic valve and the location of the coronary ostium.

Entities:  

Mesh:

Year:  1998        PMID: 9786591     DOI: 10.1007/BF02483973

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  6 in total

1.  Congenital quadricuspid aortic valve associated with aortic regurgitation.

Authors:  S Aoyagi; T Kawara; H Yasunaga; K Kosuga; K Oishi
Journal:  Thorac Cardiovasc Surg       Date:  1992-08       Impact factor: 1.827

2.  Transesophageal echocardiographic findings of quadricuspid aortic valve.

Authors:  C P Lai; S Koyanagi; J Sadoshima; A Takeshita; K Tokunaga
Journal:  Jpn Heart J       Date:  1991-09

3.  Congenital quadricuspid aortic valve with displacement of the left coronary orifrice.

Authors:  F Robicsek; P W Sanger; H K Daugherty; C C Montgomery
Journal:  Am J Cardiol       Date:  1969-02       Impact factor: 2.778

4.  Four-cusped aortic valve with significant hemodynamic abnormality.

Authors:  D I Peretz; G H Changfoot; R H Gourlay
Journal:  Am J Cardiol       Date:  1969-02       Impact factor: 2.778

5.  Diagnosis of incompetent quadricuspid aortic valve by two-dimensional echocardiography.

Authors:  R L Herman; I S Cohen; K Glaser; E W Newcomb
Journal:  Am J Cardiol       Date:  1984-03-15       Impact factor: 2.778

6.  Quadricuspid aortic valve and single coronary ostium.

Authors:  H S Kim; R A McBride; J L Titus
Journal:  Arch Pathol Lab Med       Date:  1988-08       Impact factor: 5.534

  6 in total
  1 in total

1.  Quadricuspid Aortic Valve: A Case Report and Review of the Literature.

Authors:  Ketty Savino; Elisa Quintavalle; Giuseppe Ambrosio
Journal:  J Cardiovasc Echogr       Date:  2015 Jul-Sep
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.