Literature DB >> 9784749

An ion funnel interface for improved ion focusing and sensitivity using electrospray ionization mass spectrometry.

S A Shaffer1, D C Prior, G A Anderson, H R Udseth, R D Smith.   

Abstract

To improve upon the already impressive sensitivity achievable with electrospray ionization sources, a novel electrohydrodynamic ion funnel interface has been developed and implemented with a triple-quadrupole mass spectrometer. The ion funnel interface effectively consists of a series of ring electrodes of increasingly small internal diameters to which rf and dc electric potentials are coapplied. In the 1-10-Torr pressure range, the electric fields cause the collisionally damped ions to be more effectively focused and transmitted as a collimated ion beam. This paper describes the ion funnel design and presents an evaluation of its performance using a triple-quadrupole mass spectrometer. Ion transmission and m/z discriminating parameters (resulting in both effective low- and high-m/z cutoffs) are presented based upon both ion current measurements and mass spectra. Electrospray ionization mass spectra of selected protein solutions demonstrated well over 1 order of magnitude increase in signal relative to that of the instrument operated in its standard (inlet capillary-skimmer) configuration under similar conditions. The present results suggest that it will be feasible to realize close to 100% ion transmission efficiency for analytically relevant ions through the electrospray ionization interface and into the mass analyzer.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9784749     DOI: 10.1021/ac9802170

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  59 in total

1.  Initial implementation of an electrodynamic ion funnel with Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  M E Belov; M V Gorshkov; H R Udseth; G A Anderson; A V Tolmachev; D C Prior; R Harkewicz; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2000-01       Impact factor: 3.109

2.  Delineating diseases by IMS-MS profiling of serum N-linked glycans.

Authors:  Dragan Isailovic; Manolo D Plasencia; Maissa M Gaye; Sarah T Stokes; Ruwan T Kurulugama; Vitara Pungpapong; Min Zhang; Zuzana Kyselova; Radoslav Goldman; Yehia Mechref; Milos V Novotny; David E Clemmer
Journal:  J Proteome Res       Date:  2011-12-30       Impact factor: 4.466

3.  Data-independent proteomic screen identifies novel tamoxifen agonist that mediates drug resistance.

Authors:  Shawna Mae Hengel; Euan Murray; Simon Langdon; Larry Hayward; Jean O'Donoghue; Alexandre Panchaud; Ted Hupp; David R Goodlett
Journal:  J Proteome Res       Date:  2011-09-21       Impact factor: 4.466

4.  Differentiation of compact and extended conformations of di-ubiquitin conjugates with lysine-specific isopeptide linkages by ion mobility-mass spectrometry.

Authors:  Ji Eun Jung; Nicholas A Pierson; Andreas Marquardt; Martin Scheffner; Michael Przybylski; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-24       Impact factor: 3.109

5.  Numerical analysis of ion-funnel transmission efficiency in an API-MS system with a continuum/microscopic approach.

Authors:  Sergey Gimelshein; Taylor Lilly; Eugene Moskovets
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-05       Impact factor: 3.109

Review 6.  New mass spectrometry technologies contributing towards comprehensive and high throughput omics analyses of single cells.

Authors:  Sneha P Couvillion; Ying Zhu; Gabe Nagy; Joshua N Adkins; Charles Ansong; Ryan S Renslow; Paul D Piehowski; Yehia M Ibrahim; Ryan T Kelly; Thomas O Metz
Journal:  Analyst       Date:  2019-01-28       Impact factor: 4.616

7.  An IMS-IMS threshold method for semi-quantitative determination of activation barriers: Interconversion of proline cis↔trans forms in triply protonated bradykinin.

Authors:  Nicholas A Pierson; David E Clemmer
Journal:  Int J Mass Spectrom       Date:  2015-02-01       Impact factor: 1.986

8.  A liquid injection field desorption/ionization-electrospray ionization combination source for a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  H Bernhard Linden; Jürgen H Gross
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-18       Impact factor: 3.109

9.  Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler.

Authors:  J Will Thompson; John W Eschelbach; Richard T Wilburn; James W Jorgenson
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

10.  High-resolution ion cyclotron mobility spectrometry.

Authors:  Samuel I Merenbloom; Rebecca S Glaskin; Zachary B Henson; David E Clemmer
Journal:  Anal Chem       Date:  2009-02-15       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.