Literature DB >> 9780995

Prognostic value of intraoperative blood flow measurements in vascular access surgery.

C P Johnson1, Y R Zhu, C Matt, C Pelz, A M Roza, M B Adams.   

Abstract

BACKGROUND: The purpose of this study was to correlate intraoperative blood flow measurements with outcome in vascular access surgery.
METHODS: In 303 patients, 389 vascular access operations were performed. Intraoperative blood flow measurements were made immediately following construction of 227 autogenous and 162 prosthetic arteriovenous fistulas (AVFs) using a handheld flowprobe. Blood flow measurements were stratified by demographic variables such as age, race, sex, and presence of diabetes and were correlated with primary and secondary (assisted) patency. Statistical methods included life-table analysis and Cox proportional hazards model.
RESULTS: Blood flow increased progressively from distal to proximal access sites and was not significantly affected by age, race, sex, or presence of diabetes. Autogenous AVFs with flow rates at or below 320 mL/min and polytetrafluoroethylene (PTFE) grafts with flow rates at or below 400 mL/min had significantly worse primary and secondary patency rates compared to their higher flow counterparts at all sites. Using hazard analysis flow rate was the single most important determinant of primary and secondary patency. PTFE grafts with flow rates at or below 400 mL/min also required more interventions (1.58 per patient-year) and failed sooner (median time, 0.5 +/- 4.7 months) than grafts with flow rates above 400 mL/min (1.08 interventions per patient-year; P = .03; median time, 1.6 +/- 5.0 months; P = .003).
CONCLUSIONS: Intraoperative measurements of access blood flow provide objective, reliable data that correlate with outcome. Routine use of this technology might lead to more efficient management of patients undergoing hemodialysis access surgery.

Entities:  

Mesh:

Year:  1998        PMID: 9780995     DOI: 10.1067/msy.1998.91364

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  3 in total

1.  U-vein compressor improves early haemodynamic outcomes in radiocephalic arterio-venous fistulae in under 2-mm superficial veins.

Authors:  Mustafa Seren; Omer Faruk Cicek; Mustafa Cuneyt Cicek; Ali Umit Yener; Mahmut Ulaş; Muharrem Tola; Alper Uzun
Journal:  Cardiovasc J Afr       Date:  2015 Jan-Feb       Impact factor: 1.167

2.  Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis.

Authors:  Jonggeun Lee; Seogjae Lee; Jee Won Chang; Su Wan Kim; Jung-Kook Song
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2020-06-05

3.  Effect of lower extremity bypass surgery on inflammatory reaction and endothelial dysfunction in type 2 diabetic patients.

Authors:  Pei-Hsuan Tsai; Jun-Jen Liu; Szu-Yuan Chou; Yao-Chung Chang; Sung-Ling Yeh
Journal:  Mediators Inflamm       Date:  2009-04-05       Impact factor: 4.711

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.